LiftMaster K030B0652-1 Motor Capacitor — 89µF, 120V
The LiftMaster K030B0652-1 is the manufacturer-listed 89µF, 120V motor-capacitor replacement for selected residential garage-door openers. The current manufacturer compatibility information includes 8587, 8587W, 8587WL and 85870 arrangements. Match the exact opener, capacitor and mounting before ordering. This is a motor-circuit component, separate from the motor and logic board; the voltage designation does not mean every 120V opener uses this capacitance. Select the replacement by the complete part number and the installed equipment configuration. A similar photograph or a shared LiftMaster brand name does not establish interchangeability. Confirm the applicable service drawing before ordering so the repair addresses the correct component and its related mounting, connection and operating requirements.
Compatibility — Models, Versions and Exclusions
| Model or selection point | Compatibility requirement |
|---|---|
| Manufacturer-listed 8587-family arrangements | Confirm the complete model and service reference. |
| Other120V openers | Voltage alone does not establish capacitor compatibility. |
| Different capacitance ratings | Do not substitute to alter motor behavior. |
| Motor and main board | Separate components; capacitor replacement is not complete drive renewal. |
Identify the Assembly and Plan the Repair
A humming motor or failed start does not prove the capacitor is the only failed part. Have qualified service personnel check the circuit and mechanical load. A binding door, damaged motor or connection fault may need separate correction before the replacement is fitted.
Capacitors can retain stored energy after power is disconnected. Use qualified service and the exact safe handling procedure rather than an improvised discharge method. Match the specified capacitance, voltage designation, terminals and mounting and do not borrow a value from a similar opener. Restore covers and complete the opener’s required operating and reversal tests after repair.
An electrical symptom does not identify the failed component by itself. Have qualified service personnel inspect the supply, wiring, connections and equipment condition before replacing parts. Record existing labels and terminal references with power safely isolated. A replacement should restore the documented circuit arrangement; it should not be used to change operating voltage, defeat a protective function or compensate for a mechanical load that the equipment cannot safely move.
Compare the delivered item with the approved service reference before installation. The installer must obtain the equipment-specific wiring, mounting and commissioning instructions rather than infer them from the appearance of the part. Keep conductors clear of moving components and reinstall the intended covers. After the repair, check the original complaint and the equipment’s required operating and safety functions; a successful power-up alone is not a complete service test.
Specifications and Product Identification
| Specification | Details |
|---|---|
| Ordering reference | K030B0652-1 |
| Capacitance | 89µF |
| Manufacturer voltage designation | 120V |
| Listed examples | 8587, 8587W, 8587WL, 85870 |
| Aliases | 30B652, 30B0652, 030B0652-1, 030B0652 |
Before Ordering
- Confirm K030B0652-1 or a documented alias.
- Match 89µF and the 120V designation.
- Verify the exact opener and mounting arrangement.
- Diagnose motor, wiring and door resistance.
Package Contents and Separate Requirements
This offer identifies the motor capacitor. Motor, mounting bracket, wiring harness, gear set, logic board and complete opener are separate unless expressly included. Confirm current connection and mounting pieces with the supplier. A capacitor-only order does not provide a full motor kit or establish that every motor fault can be resolved by this component.
Safety Warnings — Read Before Installation or Service
- WARNING: Electrical service can expose hazardous voltage and moving equipment. Use qualified service personnel and electrical personnel where required.
- Disconnect every applicable mains, battery and auxiliary supply before work. Follow the equipment instructions for stored energy and safe isolation.
- Capacitors can retain hazardous stored energy after isolation. Use qualified service personnel and the exact safe handling procedure; do not improvise a discharge method or substitute capacitance.
- Restore covers and wiring protection, then complete the model-specific functional and safety checks before returning the installation to normal use.
Related Products and Important Differences
- CPS-U monitored photo eyes — separate protection devices for approved commercial-door controls; match the operator and environment.
- TDC12X1BMC MAXUM trolley operator — a complete-operator comparison, not evidence that this legacy service part fits MAXUM.
Frequently Asked Questions
What capacitance is listed?
The manufacturer specifies 89µF.
Does 120V mean it fits every 120V opener?
No. Capacitance, circuit and physical mounting must match.
Is a motor included?
No motor is promised.
Can it still store energy after isolation?
Yes. Qualified personnel must follow the correct capacitor-handling procedure.
Need Help Confirming the Right Product?
Contact Garage-DoorParts.com before ordering. Send the full equipment model, readable part labels and photographs of the installed assembly. Include the dimensions, electrical configuration or accessory details relevant to your project so the listing can be checked against the actual installation.
Details
Need Help With Compatibility?
Not sure if this is the correct part for your garage door, operator, gate system, or application? Contact Us before ordering — we’re happy to help.
Garage-DoorParts.com carries a large selection of residential and commercial parts, and many components can look similar while having important differences in dimensions, model numbers, voltage, mounting, or compatibility.
For the best assistance, please provide as much information as possible, including the manufacturer, model number, part number, door or operator type, dimensions, and clear photos of the existing part or equipment.
Our goal is to help you identify the correct product before you order and reduce the possibility of ordering an incompatible part.
Contact Us with your product questions and compatibility information, and we’ll do our best to point you in the right direction.
Shipping & Returns
We strive to process and ship all orders in a timely manner, working diligently to ensure that your items are on their way to you as soon as possible.
We are committed to ensuring a positive shopping experience for all our customers. If for any reason you wish to return an item, we invite you to reach out to our team for assistance, and we will evaluate every return request with care and consideration.