LiftMaster CPSUN4G Heavy-Duty Monitored Through-Beam Photo Eyes — Black

LiftMaster CPSUN4G Heavy-Duty Monitored Through-Beam Photo Eyes — Black

$265.32
Skip to product information
LiftMaster CPSUN4G Heavy-Duty Monitored Through-Beam Photo Eyes — Black

LiftMaster CPSUN4G Heavy-Duty Monitored Through-Beam Photo Eyes — Black

CPSUN4G
$265.32
Shipping calculated at checkout.

The LiftMaster CPSUN4G Commercial Protector System is a black, heavy-duty monitored through-beam photo-eye pair for supported commercial-door and gate operators. The source specifies sensing distance up to 45 feet and a NEMA 4 enclosure rating. An emitter and receiver face one another across the protected zone, allowing the approved control system to detect an interrupted beam. Select these sensors using the exact operator’s approved-device information and installation instructions; their environmental rating and range do not make them universal replacements for every LiftMaster sensor.

Compatibility — Models, Versions and Exclusions

Model or selection point Compatibility requirement
CPS-UN4 / store SKU CPSUN4 Related separately listed sensor model covered by the shared manual; confirm the required version before ordering.
Commercial Logic 3 / 4 / 5 and Medium-Duty Logic Listed in the manufacturer manual; follow the exact operator wiring requirements.
FDC / FDCL / FDO / LGE Documented commercial-door families; verify installed configuration.
Listed legacy and U-series gate operators Use the manual’s model list and the operator’s approved protection arrangement.
CPS-U indoor sensors Different enclosure and range; compare application requirements.
Residential opener sensors No universal interchangeability with these commercial photo eyes.

Plan Protection Coverage and a Clear Beam Path

Position the emitter and receiver to cover the required hazard zone with a stable, unobstructed beam. The mounting surface must remain secure as the gate or door moves, and surrounding hardware must not cross the sensing path. Assess the opening and the environmental exposure before selecting locations. One pair protects its own beam path; additional hazards may require separate devices.

A recurring sensor fault can involve alignment, contamination, sunlight, wiring damage or an unsuitable connection rather than a failed eye. Inspect those conditions before replacement. Use the manufacturer procedure to verify both normal detection and monitored fault behavior. Adding a second pair or another protection device may require a specific interface arrangement; do not simply connect extra sensors to an input without checking the controller instructions.

Specifications and Product Identification

Specification Details
Part number CPSUN4G
System Commercial Protector System
Sensing arrangement Monitored through-beam pair
Source maximum range 45 feet
Enclosure rating NEMA 4
Color Black

Before Ordering

  • Record the full operator model and control generation.
  • Check the approved device list and required protection zones.
  • Measure the opening and confirm a stable beam path within range.
  • Plan wiring, mounting and the required detection and fault tests.

Package Contents and Separate Requirements

This offer identifies the monitored emitter-and-receiver pair. Confirm the current package for brackets and mounting pieces. Field wiring, conduit, site-specific anchors, additional interfaces and the operator are separate requirements unless expressly included. A NEMA 4 sensor housing does not make every field connection weatherproof; the installer must preserve the complete installation’s required protection against moisture and mechanical damage.

Safety Warnings — Read Before Installation or Service

  • WARNING: Incorrect photo-eye installation can leave a crushing hazard. Use a qualified installer and follow the operator instructions for every entrapment zone.
  • Disconnect power before wiring. The manufacturer manual specifies beam heights no higher than 6 inches for commercial doors and 27.5 inches for gates; follow the complete model-specific requirements.
  • Never bypass monitoring or leave sensors misaligned to force operation. Keep lenses clean and replace damaged wiring or housings.
  • Test beam interruption and required fault response before normal use, then repeat inspections as directed by the equipment instructions.

Related Products and Important Differences

Frequently Asked Questions

Does it need a reflector?

No. This is a through-beam emitter-and-receiver arrangement, not a reflective sensor.

What is the listed maximum distance?

The source specifies up to 45 feet; installation conditions and proper alignment still matter.

Can it replace any residential sensor?

No. Match the approved operator and input arrangement.

Does one pair protect every hazard?

No. Protection coverage must be evaluated across the complete installation.

Need Help Confirming the Right Product?

Contact Garage-DoorParts.com before ordering. Send the full equipment model, readable part labels and photographs of the installed assembly. Include the dimensions, electrical configuration or accessory details relevant to your project so the listing can be checked against the actual installation.

Details

Need Help With Compatibility?

Not sure if this is the correct part for your garage door, operator, gate system, or application? Contact Us before ordering — we’re happy to help.

Garage-DoorParts.com carries a large selection of residential and commercial parts, and many components can look similar while having important differences in dimensions, model numbers, voltage, mounting, or compatibility.

For the best assistance, please provide as much information as possible, including the manufacturer, model number, part number, door or operator type, dimensions, and clear photos of the existing part or equipment.

Our goal is to help you identify the correct product before you order and reduce the possibility of ordering an incompatible part.

Contact Us with your product questions and compatibility information, and we’ll do our best to point you in the right direction.

Shipping & Returns

We strive to process and ship all orders in a timely manner, working diligently to ensure that your items are on their way to you as soon as possible.

We are committed to ensuring a positive shopping experience for all our customers. If for any reason you wish to return an item, we invite you to reach out to our team for assistance, and we will evaluate every return request with care and consideration.