The LiftMaster AUXCARD adds auxiliary switching contacts to supported LiftMaster solid-state commercial-door operator controls. It provides normally open and normally closed contact arrangements for documented operating conditions, while the connected device requires its own appropriate external power source. Match the operator generation, option-board slot and intended accessory load before ordering. This is the AUXCARD platform, with its own ratings and programming restrictions; the newer MAXUM AUXREL accessory is a different board and must not be substituted simply because both provide relay outputs.

Compatibility — Models, Versions and Exclusions

Model or selection point Compatibility requirement
Operators specifying AUXCARD Confirm the option slot and exact logic generation.
N4 / N4X configurations Open terminals are unavailable for auxiliary use; remote relay control is not available.
External indicator or control circuit Match the load and contact specifications.
Incandescent loads Excluded by the manufacturer instructions.
MAXUM AUXREL Different accessory; no interchangeable fit established.

Plan the Contact Function and the External Power Circuit

First determine what the external device must do when the door moves, stops or loses power. A contact state is not the same as a supply-voltage output. Ask the installer to document the intended response and check the applicable function table before selecting the interface. That avoids an indicator behaving opposite to the intended condition or remaining misleading when the operator is unavailable.

Inspect the existing control enclosure and confirm the required option slot is suitable and available. Identify every external circuit connected to the proposed board so service isolation covers more than the door operator alone. After installation, verify actual behavior through the complete door cycle and relevant stopped or power-loss conditions. Do not treat an auxiliary indication as proof that the doorway is clear or that a required safety device is working.

Specifications and Product Identification

Specification Details
Model AUXCARD
Product Auxiliary contacts option board
Control platform Supported LiftMaster solid-state commercial operators
Contact arrangements Normally open / normally closed
Maximum stated contact rating 10A at 240VAC; application restrictions apply
Load exclusion Not for incandescent loads
External device power Separate suitable source required

Before Ordering

  • Record the complete operator and control-board generation.
  • Confirm AUXCARD is specified and the correct option slot is available.
  • Identify external power, load type and required contact behavior.
  • Check N4/N4X limitations and plan a complete functional test.

Package Contents and Separate Requirements

This offer identifies the AUXCARD option board. External lights, horns, fans, power supplies, remotes, field wiring and a complete operator are not promised as included. Confirm the current package for mounting or connection pieces. Establish the full accessory circuit separately; a relay board alone does not provide every component needed to power or mount a signaling device. Select any additional interface equipment by its own documented electrical requirements.

Safety Warnings — Read Before Installation or Service

  • WARNING: Isolate operator power and every separately powered external circuit before installing or servicing this board. Use qualified electrical service personnel.
  • Do not exceed the manufacturer contact limit, and do not connect incandescent loads. A maximum contact rating is not approval for every device of that current.
  • Keep auxiliary wiring properly enclosed and separated as required. Do not adapt a mismatched board or bypass protection to obtain a desired signal.
  • Test door operation and all required safety devices after service. Auxiliary contacts do not replace monitored protection or an emergency-stop system.

Related Products and Important Differences

Frequently Asked Questions

Does AUXCARD power the external device?

The accessory circuit needs its own appropriate external power source.

Can it switch an incandescent lamp?

No. The manufacturer instructions exclude incandescent loads.

Is it the same as AUXREL?

No. AUXREL belongs to a different control platform and has different requirements.

Are all functions available on N4/N4X?

No. Those operators have specific terminal and remote-control restrictions.

Need Help Confirming the Right Product?

Contact Garage-DoorParts.com before ordering. Send the full equipment model, readable part labels and photographs of the installed assembly. Include the dimensions, electrical configuration or accessory details relevant to your project so the listing can be checked against the actual installation.

Details

Need Help With Compatibility?

Not sure if this is the correct part for your garage door, operator, gate system, or application? Contact Us before ordering — we’re happy to help.

Garage-DoorParts.com carries a large selection of residential and commercial parts, and many components can look similar while having important differences in dimensions, model numbers, voltage, mounting, or compatibility.

For the best assistance, please provide as much information as possible, including the manufacturer, model number, part number, door or operator type, dimensions, and clear photos of the existing part or equipment.

Our goal is to help you identify the correct product before you order and reduce the possibility of ordering an incompatible part.

Contact Us with your product questions and compatibility information, and we’ll do our best to point you in the right direction.

Shipping & Returns

We strive to process and ship all orders in a timely manner, working diligently to ensure that your items are on their way to you as soon as possible.

We are committed to ensuring a positive shopping experience for all our customers. If for any reason you wish to return an item, we invite you to reach out to our team for assistance, and we will evaluate every return request with care and consideration.

Related products