LiftMaster K25-4003-K Overload Service Component — 2.6–3.7A Range

LiftMaster K25-4003-K Overload Service Component — 2.6–3.7A Range

$150.63
Skip to product information
LiftMaster K25-4003-K Overload Service Component — 2.6–3.7A Range

LiftMaster K25-4003-K Overload Service Component — 2.6–3.7A Range

K25-4003-K
$150.63
Shipping calculated at checkout.

The LiftMaster K25-4003-K identifies the overload service component with a 2.6–3.7A range for the applicable commercial door or gate operator circuit. Select it by the approved motor-protection arrangement and exact service reference. The range is not a direction to choose the highest setting, a branch-circuit breaker rating or permission to increase the load on an operator that repeatedly trips. Select the replacement by the complete part number and the installed equipment configuration. A similar photograph or a shared LiftMaster brand name does not establish interchangeability. Confirm the applicable service drawing before ordering so the repair addresses the correct component and its related mounting, connection and operating requirements.

Compatibility — Models, Versions and Exclusions

Model or selection point Compatibility requirement
Approved overload arrangement Confirm the exact K25-4003-K application.
Motor current requirement Use the documented protection setting for that motor.
Other overload ranges An overlapping range alone does not establish interchangeable mounting or protection.
Branch circuit protection This item does not replace the installation’s separate supply protection.

Identify the Assembly and Plan the Repair

Repeated overload operation calls for diagnosis of the motor, supply and driven equipment. A binding door or gate, damaged motor or electrical fault must be corrected rather than hidden by increasing a protection setting. Have qualified service personnel identify whether the overload itself has failed before replacing it.

Match the contactor or starter arrangement, mounting, reset behavior and documented current range. This listing does not establish every electrical rating or permit guessing a setting from the operator’s horsepower alone. Record the motor nameplate and existing protection component so the current replacement and its setup can be confirmed for the complete circuit.

An electrical symptom does not identify the failed component by itself. Have qualified service personnel inspect the supply, wiring, connections and equipment condition before replacing parts. Record existing labels and terminal references with power safely isolated. A replacement should restore the documented circuit arrangement; it should not be used to change operating voltage, defeat a protective function or compensate for a mechanical load that the equipment cannot safely move.

Specifications and Product Identification

Specification Details
Ordering reference K25-4003-K
Component Overload protection service item
Identified range 2.6–3.7A
Application Exact approved commercial operator circuit must match
Setting requirement Determine from the equipment and motor specifications

Before Ordering

  • Record the operator, motor and existing overload labels.
  • Verify the 2.6–3.7A service requirement and exact part number.
  • Diagnose the cause of repeated trips or heating.
  • Obtain the approved installation and protection-setting instructions.

Package Contents and Separate Requirements

This offer identifies the overload service component. Confirm current mounting, connection and reset details. A complete contactor or starter, electrical box, motor, branch-circuit breaker and complete operator are not established as included with this overload reference.

Safety Warnings — Read Before Installation or Service

  • WARNING: Electrical service can expose hazardous voltage and moving equipment. Use qualified service personnel and electrical personnel where required.
  • Disconnect every applicable mains, battery and auxiliary supply before work. Follow the equipment instructions for stored energy and safe isolation.
  • Never bypass the overload or raise its setting to conceal a fault. Diagnose the motor, supply and driven equipment and use the approved protection setting.
  • Restore covers and wiring protection, then complete the model-specific functional and safety checks before returning the installation to normal use.

Related Products and Important Differences

Frequently Asked Questions

Should I set it to 3.7A to prevent trips?

No. Use the approved setting for the exact motor and circuit, and diagnose the cause of repeated overload operation.

Is it a replacement supply breaker?

No branch-circuit breaker function is established. It is the specified overload service component.

Will another overlapping range work?

Range alone is insufficient. The complete protection characteristics, mounting and approved service match must be verified.

Will replacement fix a binding gate or door?

No. Mechanical resistance and other causes of abnormal motor loading require their own repair before normal operation resumes.

Need Help Confirming the Right Product?

Contact Garage-DoorParts.com before ordering. Send the full equipment model, readable part labels and photographs of the installed assembly. Include the dimensions, electrical configuration or accessory details relevant to your project so the listing can be checked against the actual installation.

Details

Need Help With Compatibility?

Not sure if this is the correct part for your garage door, operator, gate system, or application? Contact Us before ordering — we’re happy to help.

Garage-DoorParts.com carries a large selection of residential and commercial parts, and many components can look similar while having important differences in dimensions, model numbers, voltage, mounting, or compatibility.

For the best assistance, please provide as much information as possible, including the manufacturer, model number, part number, door or operator type, dimensions, and clear photos of the existing part or equipment.

Our goal is to help you identify the correct product before you order and reduce the possibility of ordering an incompatible part.

Contact Us with your product questions and compatibility information, and we’ll do our best to point you in the right direction.

Shipping & Returns

We strive to process and ship all orders in a timely manner, working diligently to ensure that your items are on their way to you as soon as possible.

We are committed to ensuring a positive shopping experience for all our customers. If for any reason you wish to return an item, we invite you to reach out to our team for assistance, and we will evaluate every return request with care and consideration.

Related products