LiftMaster CPS3 / CPSIII Option Card with CPS-U Photo Eyes – 30' Monitored Commercial Safety Kit
The LiftMaster CPS3 / CPSIII Option Card with CPS-U Photo Eyes is a monitored commercial safety kit designed for compatible LiftMaster commercial door operators requiring an additional set of photoelectric safety sensors.
The kit combines a CPS3 interface card with LiftMaster CPS-U through-beam commercial photo eyes, allowing compatible operator systems to support a second monitored entrapment-protection device.
Specifications
-
Brand: LiftMaster
-
Model: CPS3 / CPSIII
-
Product Type: Commercial Photo Eye & Interface Card Kit
-
Photo Eye Model: CPS-U
-
Sensor Type: Monitored Through-Beam Infrared
-
Maximum Sensing Range: 30 ft
-
Enclosure Rating: NEMA 1
-
Installation Environment: Indoor
-
Safety Standard: UL 325
-
Application: Commercial Overhead Door Operators
-
CPS3 Interface Card: 041K0811
-
Sensor Configuration: Emitter and Receiver
-
Mounting: Floor or Track Mount
Kit Includes
-
LiftMaster CPS3 interface / option card
-
CPS-U sending photo eye
-
CPS-U receiving photo eye
-
Steel mounting brackets
-
Installation hardware as supplied with the kit
Designed for a Second Set of Monitored Photo Eyes
The CPS3 card allows compatible LiftMaster commercial operators to accept an additional monitored entrapment-protection device.
This is particularly useful on installations where two separate monitored safety zones are required.
Depending on the operator and control-board generation, the CPS3 interface may support compatible LiftMaster monitored devices including:
-
CPS-U photo eyes
-
CPS-UN4 photo eyes
-
CPS-OPEN4 photo eyes
-
CPS-RPEN4 photo eyes
-
Compatible monitored sensing edges
This listing includes the CPS-U photo eye set.
CPS-U Commercial Photo Eyes
The included CPS-U sensors create an infrared beam between a sending eye and receiving eye across the door opening.
Key CPS-U features include:
-
Up to 30 ft sensing range
-
Dual-sided infrared sensing system
-
Monitored entrapment protection
-
Alignment indicator lights
-
High-visibility yellow housings
-
NEMA 1 enclosure
-
Indoor commercial applications
-
UL 325 compliant design
If the beam is interrupted while the door is closing, the compatible operator responds according to its programmed safety logic.
Compatible Operator Systems
The CPS3 interface card is used with select LiftMaster commercial operator control systems, including compatible:
-
Logic 3.0 operators
-
Logic 4.0 operators
-
Logic 5.0 operators
-
Select Medium-Duty Logic operators
Compatibility depends on the exact operator model, logic-board generation, and existing safety-device configuration.
Always verify the operator manual or replacement-parts diagram before ordering.
Timer-to-Close Support
When installed on a compatible LiftMaster commercial operator, the CPS3 system can support monitored safety requirements associated with Timer-to-Close operation.
Timer-to-Close automatically commands the door to close after a programmed period, making proper monitored entrapment protection especially important.
Availability and programming of this feature depend on the operator and logic-board configuration.
Important Compatibility Information
This kit should not be confused with:
-
CPS-U photo eyes sold without the CPS3 card
-
CPS-UN4 NEMA 4 photo eyes
-
CPS-OPEN4 monitored dual-sided photo eyes
-
CPS-RPEN4 retro-reflective photo eyes
-
CPSN4 systems for mechanical operators
Before ordering, confirm:
-
LiftMaster operator model
-
Logic-board generation
-
Existing monitored safety devices
-
Whether a second set of photo eyes is required
-
Indoor or outdoor installation environment
-
Required sensing range
Indoor Use
The included CPS-U photo eyes are rated NEMA 1 and are intended primarily for indoor installations.
For damp, wash-down, dusty, or outdoor environments, a NEMA 4-rated LiftMaster photoeye system may be more appropriate.
Installation & Safety
Commercial photoelectric sensors form part of the operator's entrapment-protection system.
Installation, wiring, positioning, programming, and testing must follow LiftMaster instructions and applicable safety requirements.
After installation, test all photo eyes, monitored edges, door controls, travel limits, and other safety devices before returning the commercial door to service.
Professional installation by a qualified commercial door technician is recommended.
If you are unsure whether the LiftMaster CPS3 / CPSIII kit is correct for your operator, contact Garage-DoorParts.com with the operator model number, logic-board information, and photos of the existing safety system before ordering.
Details
Need Help With Compatibility?
Not sure if this is the correct part for your garage door, operator, gate system, or application? Contact Us before ordering — we’re happy to help.
Garage-DoorParts.com carries a large selection of residential and commercial parts, and many components can look similar while having important differences in dimensions, model numbers, voltage, mounting, or compatibility.
For the best assistance, please provide as much information as possible, including the manufacturer, model number, part number, door or operator type, dimensions, and clear photos of the existing part or equipment.
Our goal is to help you identify the correct product before you order and reduce the possibility of ordering an incompatible part.
Contact Us with your product questions and compatibility information, and we’ll do our best to point you in the right direction.
Shipping & Returns
We strive to process and ship all orders in a timely manner, working diligently to ensure that your items are on their way to you as soon as possible.
We are committed to ensuring a positive shopping experience for all our customers. If for any reason you wish to return an item, we invite you to reach out to our team for assistance, and we will evaluate every return request with care and consideration.
Shop The Full Collection