LiftMaster CAP4AP Smart Access Controller — Two Doors or Four Access Points

LiftMaster CAP4AP Smart Access Controller — Two Doors or Four Access Points

$817.40
Skip to product information
LiftMaster CAP4AP Smart Access Controller — Two Doors or Four Access Points

LiftMaster CAP4AP Smart Access Controller — Two Doors or Four Access Points

CAP4AP
$817.40
Shipping calculated at checkout.

The LiftMaster CAP4AP is an outdoor-rated smart access controller for managing either two doors or four access points through the myQ Community platform. It combines network connectivity with configurable control connections in an enclosure designed for installation without a separate NEMA box. The manufacturer identifies Wi-Fi, an Ethernet PoE power option and OSDP encrypted communication. Plan the controller around the actual readers, locks, request-to-exit devices and monitored inputs: four relay outputs do not automatically mean four fully equipped bidirectional doors, and the controller is not itself a video intercom or gate operator.

Compatibility — Models, Versions and Exclusions

Model or selection point Compatibility requirement
Two-door or four-access-point design Confirm the full reader, relay and supervised-input allocation.
OSDP readers Verify approved reader, protocol configuration and secure-communication setup.
Wiegand devices Match the documented input and credential requirements.
Electric locks and gate-control inputs Check separate power needs, relay ratings and approved control wiring.
Video-intercom or complete operator needs Separate equipment; CAP4AP does not include those functions as a complete system.

Plan the Openings, Network and Power Together

Begin with an opening-by-opening schedule identifying each reader, lock, door-position input and exit function. Confirm how the controller’s available connections will be allocated before choosing accessories. A relay command is not a substitute for the separate protection functions required at an automated gate, and access-control decisions must preserve the intended emergency egress at every controlled door.

Check network availability and select the approved power method for the installation. Wi-Fi connectivity does not mean the controller or connected locks operate without power, while PoE requires suitable network equipment and cabling. Coordinate account commissioning, user permissions and access schedules with the authorized site administrator. Installation of the controller alone does not establish a subscription, credential enrollment or the complete access policy for the property.

Specifications and Product Identification

Specification Details
Model CAP4AP
Documented capacity Either two doors or four access points
Relay outputs Four; configurable mapping in myQ Community
Source input description Four supervised inputs, two Wiegand inputs, four OSDP inputs
Power options 24V DC adapter, provided, or approved PoE
Enclosure ratings IP54 / IK07
Operating temperature -4°F to 122°F (-20°C to 50°C)
Dimensions 9.25 in. H × 10.29 in. W × 2.58 in. D

Before Ordering

  • Define two-door or four-access-point operation and all required inputs.
  • Confirm reader protocol, credentials and lock power requirements.
  • Verify network coverage, approved power and mounting environment.
  • Plan myQ Community commissioning and test every opening’s release behavior.

Package Contents and Separate Requirements

This offer identifies the CAP4AP controller. The manufacturer states that a 24V DC power adapter is provided; confirm the complete current carton and mounting accessories. Readers, credentials, locks, a PoE network switch, gate operators, video-intercom equipment and any service subscription are separate unless expressly included in the supplier package. The enclosure has provision for a lock; do not assume a separate lock is included merely because the enclosure supports one.

Safety Warnings — Read Before Installation or Service

  • WARNING: Access-control installation must preserve emergency egress and safe door or gate operation. Use a qualified access-control installer.
  • Disconnect applicable supplies before wiring, including separate lock power. Observe the documented relay and reader electrical limits.
  • Preserve the enclosure seals and approved cable entries. IP54 does not authorize submersion or unrestricted pressure washing.
  • Test credentials, exit requests, door status and required emergency-release behavior. At automated gates, also verify the independent entrapment-protection system.

Related Products and Important Differences

  • KPW250 wireless keypad — a different access method requiring a compatible receiver; not an OSDP or Wiegand reader substitution.
  • LMRRUL monitored photo eye — a separate gate-protection option for approved operators; controller relays do not replace entrapment sensing.

Frequently Asked Questions

Does CAP4AP control four complete doors?

The manufacturer specifies either two doors or four access points; confirm the required device allocation.

Is Wi-Fi the only connection option?

No. The manufacturer also identifies Ethernet with an approved PoE option.

Are readers and locks included?

No complete reader-and-lock package is promised in this controller offer.

Is CAP4AP a video intercom?

No. It is an access controller; select any required intercom equipment separately.

Need Help Confirming the Right Product?

Contact Garage-DoorParts.com before ordering. Send the full equipment model, readable part labels and photographs of the installed assembly. Include the dimensions, electrical configuration or accessory details relevant to your project so the listing can be checked against the actual installation.

Details

Need Help With Compatibility?

Not sure if this is the correct part for your garage door, operator, gate system, or application? Contact Us before ordering — we’re happy to help.

Garage-DoorParts.com carries a large selection of residential and commercial parts, and many components can look similar while having important differences in dimensions, model numbers, voltage, mounting, or compatibility.

For the best assistance, please provide as much information as possible, including the manufacturer, model number, part number, door or operator type, dimensions, and clear photos of the existing part or equipment.

Our goal is to help you identify the correct product before you order and reduce the possibility of ordering an incompatible part.

Contact Us with your product questions and compatibility information, and we’ll do our best to point you in the right direction.

Shipping & Returns

We strive to process and ship all orders in a timely manner, working diligently to ensure that your items are on their way to you as soon as possible.

We are committed to ensuring a positive shopping experience for all our customers. If for any reason you wish to return an item, we invite you to reach out to our team for assistance, and we will evaluate every return request with care and consideration.

Related products