{"product_id":"liftmaster-srdrmm","title":"LiftMaster SRDRMM Mullion Smart Reader — Multi-Technology Credential Access","description":"\u003cp\u003e\u003cstrong\u003eThe LiftMaster SRDRMM is the mullion-mount smart credential reader for supported access-control installations. The source specifies 125kHz proximity and 13.56MHz smart-card formats, a 5–16V DC supply range, and current draw of 120mA average or 170mA peak. LiftMaster also identifies the first-generation SRDRMM among readers supported for myQ mobile credentials, subject to system setup and user enrollment. Select this model for its mullion mounting arrangement and supported credentials; it is not the keypad version, a standalone door controller or a universal reader for every card at the same frequency.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eCompatibility — Models, Versions and Exclusions\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel or selection point\u003c\/th\u003e\n\u003cth\u003eCompatibility requirement\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported access-control panels\u003c\/td\u003e\n\u003ctd\u003eVerify the exact reader interface, power and configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListed proximity and smart-card formats\u003c\/td\u003e\n\u003ctd\u003eFrequency alone does not establish credential compatibility.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emyQ Community mobile access\u003c\/td\u003e\n\u003ctd\u003eRequires supported setup, user enrollment and phone permissions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRDRST \/ SRDRKP\u003c\/td\u003e\n\u003ctd\u003eDifferent mounting or keypad versions; not the same physical product.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRDRMMv2\u003c\/td\u003e\n\u003ctd\u003eA separately identified generation; confirm which revision is required.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eChoose the Credential Workflow Before the Reader\u003c\/h2\u003e\u003cp\u003eChoose the reader around the credentials and entry workflow used at the property. Check actual card or fob formats, panel settings and mobile-access requirements before replacing an existing reader. If visitors need a numeric PIN, select a documented keypad solution rather than assuming software will add a keypad to this credential-reader model.\u003c\/p\u003e\u003cp\u003eMullion mounting requires sufficient support, cable access and a suitable user position. Inspect the existing frame or surface and protect the reader wiring according to its instructions. Verify the available low-voltage supply and account for cable voltage drop and the controller’s power budget. Do not connect a 24V intercom supply directly to a reader specified for a maximum of 16V.\u003c\/p\u003e\u003ch2\u003eSpecifications and Product Identification\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSRDRMM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eMullion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e5–16V DC; power supply not included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e120mA average \/ 170mA peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSource proximity formats\u003c\/td\u003e\n\u003ctd\u003e125kHz:26-bit,30-bit,37-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSource smart formats\u003c\/td\u003e\n\u003ctd\u003e13.56MHz:32-bit MIFARE,56-bit LiftMaster\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMobile access\u003c\/td\u003e\n\u003ctd\u003eSupported myQ credentials with appropriate system configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eBefore Ordering\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIdentify the controller and exact reader interface.\u003c\/li\u003e\n\u003cli\u003eVerify credential formats, enrollment and mobile-service setup.\u003c\/li\u003e\n\u003cli\u003eConfirm mullion mounting, cable route and 5–16V DC power.\u003c\/li\u003e\n\u003cli\u003eCheck the supplied reader generation and required installation instructions.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003ePackage Contents and Separate Requirements\u003c\/h2\u003e\u003cp\u003eThis offer identifies the SRDRMM mullion smart reader. The source explicitly excludes the power supply. A controller, lock, cards, fobs, wiring and ongoing myQ Community services are not promised as included. Confirm current mounting pieces and connection details in the carton. A compatible credential still needs enrollment and access permission in the complete system; purchasing a reader does not automatically authorize existing users.\u003c\/p\u003e\u003ch2 class=\"safety-warning\"\u003eSafety Warnings — Read Before Installation or Service\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWARNING: Access-control changes must preserve required emergency egress and safe door or gate operation. Use a qualified access-control installer.\u003c\/li\u003e\n\u003cli\u003eDisconnect the applicable supply before wiring. Do not connect mains voltage to the reader’s low-voltage terminals.\u003c\/li\u003e\n\u003cli\u003eMount the reader where users cannot reach through or stand within a moving gate’s hazard area. Follow the installation instructions and applicable site requirements.\u003c\/li\u003e\n\u003cli\u003eTest authorized access, denied credentials, visitor functions and required egress after commissioning. Access authorization does not replace gate entrapment protection.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eRelated Products and Important Differences\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-wireless-security-20-keypad-metal\"\u003eKPW250 wireless keypad\u003c\/a\u003e — compare a separate wireless access method for supported gate receivers; it is not a Wiegand smart reader.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-lmrrul-monitored-retro-reflective-photo-eye\"\u003eLMRRUL monitored photo eye\u003c\/a\u003e — a separate gate-safety device for approved operators; reader authorization does not provide entrapment protection.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eDoes it include a power supply?\u003c\/h3\u003e\u003cp\u003eNo. The source specifies that the supply is not included.\u003c\/p\u003e\u003ch3\u003eDoes it have a numeric keypad?\u003c\/h3\u003e\u003cp\u003eThis is the mullion reader, not the keypad-reader model.\u003c\/p\u003e\u003ch3\u003eWill every 13.56MHz card work?\u003c\/h3\u003e\u003cp\u003eNo. The exact credential technology, format and controller setup must match.\u003c\/p\u003e\u003ch3\u003eCan it use myQ mobile credentials?\u003c\/h3\u003e\u003cp\u003eLiftMaster lists SRDRMM as supported; appropriate system setup, enrollment and phone permissions remain necessary.\u003c\/p\u003e\u003ch2\u003eNeed Help Confirming the Right Product?\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/garage-doorparts.com\/pages\/contact\"\u003eContact Garage-DoorParts.com before ordering\u003c\/a\u003e. Send the full equipment model, readable part labels and photographs of the installed assembly. Include the dimensions, electrical configuration or accessory details relevant to your project so the listing can be checked against the actual installation.\u003c\/p\u003e","brand":"Controlled Products","offers":[{"title":"Default Title","offer_id":60723297714462,"sku":"SRDRMM","price":328.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0978\/2781\/5710\/files\/srdrmm.png?v=1793244755","url":"https:\/\/garage-doorparts.com\/products\/liftmaster-srdrmm","provider":"garage-doorparts.com","version":"1.0","type":"link"}