{"product_id":"liftmaster-ppwr-mc","title":"LiftMaster PPWR-MC \/ PPWRMC Passport Wiegand Access Receiver — Security+ 2.0","description":"\u003cp\u003e\u003cstrong\u003eThe LiftMaster PPWR-MC supplier offer identifies the PPWRMC Passport credentialed access receiver. It receives supported Security+ 2.0 Passport MAX and Passport Lite remote credentials and passes compatible Wiegand data to an access-control host. This makes it suitable for a managed entrance where the controller handles access permissions. The PPWR has no relay output, so it must not be selected as a direct replacement for a standalone receiver that closes an operator command circuit.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eCompatibility — Models, Versions and Exclusions\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel or selection point\u003c\/th\u003e\n\u003cth\u003eCompatibility requirement\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Wiegand access-control hosts\u003c\/td\u003e\n\u003ctd\u003eMatch the configured bit format, facility-code handling and credential data.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePassport MAX \/ Passport Lite remotes\u003c\/td\u003e\n\u003ctd\u003eUse the supported credentialed models and configure the host permissions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPV3M \/ PPK3M \/ PPK3PHM\u003c\/td\u003e\n\u003ctd\u003eManufacturer-listed Passport MAX accessory examples; verify the exact supplied variant.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPLV1 \/ PPLK1 \/ PPLK1PH\u003c\/td\u003e\n\u003ctd\u003eManufacturer-listed Passport Lite families; package suffixes and credential assignment matter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandalone relay receivers\u003c\/td\u003e\n\u003ctd\u003eDifferent interface and system role; PPWR does not provide an equivalent relay output.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eConfigure Credential Handling at Both the Receiver and Host\u003c\/h2\u003e\u003cp\u003eThe receiver’s Wiegand format must agree with the host controller. A valid radio transmission alone does not establish that the person is authorized to enter. Confirm the credential numbering and facility-code plan before enrolling a batch of remotes, especially at properties that already use cards or fobs and need consistent access records.\u003c\/p\u003e\u003cp\u003eThe manufacturer describes pass-through and advanced modes. Pass-through sends the received credential information to the host, while advanced mode can filter or translate configured facility codes. Choose the mode deliberately and preserve the site’s settings before changes. Receiver configuration backups are useful service records, but they do not replace the host’s user permissions, schedules or credential database.\u003c\/p\u003e\u003ch2\u003eSpecifications and Product Identification\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupplier SKU\u003c\/td\u003e\n\u003ctd\u003ePPWR-MC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer reference\u003c\/td\u003e\n\u003ctd\u003ePPWRMC \/ PPWR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadio credential family\u003c\/td\u003e\n\u003ctd\u003eSecurity+ 2.0 Passport MAX and Passport Lite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput interface\u003c\/td\u003e\n\u003ctd\u003eWiegand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDocumented output formats\u003c\/td\u003e\n\u003ctd\u003e26, 30, 31, 34 and 50 bit; confirm parity where applicable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay output\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental rating\u003c\/td\u003e\n\u003ctd\u003eIP44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePublished operating temperature\u003c\/td\u003e\n\u003ctd\u003e−40°C to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eBefore Ordering\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIdentify the host controller and its supported Wiegand input format.\u003c\/li\u003e\n\u003cli\u003eConfirm the exact Passport remote family and credential assignment.\u003c\/li\u003e\n\u003cli\u003ePlan facility-code handling, permissions and the appropriate operating mode.\u003c\/li\u003e\n\u003cli\u003eVerify mounting, power, wiring and any antenna arrangement against the receiver instructions.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003ePackage Contents and Separate Requirements\u003c\/h2\u003e\u003cp\u003eThis offer identifies the Passport receiver. Confirm the current carton for its antenna, memory module and mounting items. Remote transmitters, an access-control host, field wiring, power supply and gate operator are not promised as included. The receiver’s programming keypad is for configuration; it is not a substitute for a separately selected visitor-entry keypad.\u003c\/p\u003e\u003ch2 class=\"safety-warning\"\u003eSafety Warnings — Read Before Installation or Service\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWARNING: Incorrect credential configuration can grant unintended access or prevent authorized entry. Use a qualified access-control installer and verify the site’s authorization plan.\u003c\/li\u003e\n\u003cli\u003eDisconnect the applicable power before wiring and follow the specified low-voltage supply and Wiegand connection requirements.\u003c\/li\u003e\n\u003cli\u003ePreserve required emergency egress and all gate or door safety devices. A received credential is not entrapment protection.\u003c\/li\u003e\n\u003cli\u003eTest authorized and denied credentials, button assignments and host response before putting the entrance into normal service. Protect administrator access and backup settings.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eRelated Products and Important Differences\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-star1000-commercial-receiver\"\u003eSTAR1000 commercial receiver\u003c\/a\u003e — a different receiver architecture; compare its outputs and credential-management role before choosing.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-wireless-security-20-keypad-metal\"\u003eKPW250 wireless keypad\u003c\/a\u003e — a separate access device for its supported receiver\/operator arrangement; no PPWR credential compatibility is implied.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eCan PPWR directly close a gate operator’s push-button circuit?\u003c\/h3\u003e\u003cp\u003eNo relay output is provided. Use a compatible access-control host and the documented interface.\u003c\/p\u003e\u003ch3\u003eDoes Security+ 2.0 mean every remote in that family is credential-compatible?\u003c\/h3\u003e\u003cp\u003eDo not assume that. Select supported Passport MAX or Passport Lite models and verify the receiver documentation.\u003c\/p\u003e\u003ch3\u003eDoes a saved receiver backup include all resident permissions?\u003c\/h3\u003e\u003cp\u003eDo not assume it does. Host authorization records and receiver settings serve different roles.\u003c\/p\u003e\u003ch3\u003eIs the programming keypad intended for visitor PIN entry?\u003c\/h3\u003e\u003cp\u003eIt configures the receiver. A visitor-access keypad must be selected separately for the intended system.\u003c\/p\u003e\u003ch2\u003eNeed Help Confirming the Right Product?\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/garage-doorparts.com\/pages\/contact\"\u003eContact Garage-DoorParts.com before ordering\u003c\/a\u003e. Send the full equipment model, readable part labels and photographs of the installed assembly. Include the dimensions, electrical configuration or accessory details relevant to your project so the listing can be checked against the actual installation.\u003c\/p\u003e","brand":"LiftMaster","offers":[{"title":"Default Title","offer_id":60655782330654,"sku":"PPWR-MC","price":375.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0978\/2781\/5710\/files\/ppwr.jpg?v=1793139960","url":"https:\/\/garage-doorparts.com\/products\/liftmaster-ppwr-mc","provider":"garage-doorparts.com","version":"1.0","type":"link"}