{"product_id":"liftmaster-ped42","title":"LiftMaster PED42 42-Inch Pad-Mount Gooseneck Pedestal","description":"\u003cp\u003e\u003cstrong\u003eThe LiftMaster PED42 is a 42-inch pad-mount gooseneck pedestal for compatible access-control equipment. Manufacturer literature describes a 2-by-2-inch square post with a black powder-coated finish and identifies the pedestal with supported keypad and entry-system applications. It provides a physical mounting position, not access-control electronics or a vehicle-impact barrier. Match the device’s mounting pattern, driver reach, clearances and supporting pad before ordering. The nominal pedestal height alone does not establish the finished control height or suitability for every entrance layout.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eCompatibility — Models, Versions and Exclusions\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel or selection point\u003c\/th\u003e\n\u003cth\u003eCompatibility requirement\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDocumented LiftMaster keypad applications\u003c\/td\u003e\n\u003ctd\u003eManufacturer keypad literature lists PED42; verify the device mounting pattern.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported entry-system equipment\u003c\/td\u003e\n\u003ctd\u003eConfirm load, faceplate and attachment requirements for the actual device.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExisting concrete pad\u003c\/td\u003e\n\u003ctd\u003eMust support the approved anchoring arrangement and site layout.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIn-ground mounting\u003c\/td\u003e\n\u003ctd\u003eDifferent pedestal configuration; do not treat the pad-mount model as a buried post.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVehicle-impact protection\u003c\/td\u003e\n\u003ctd\u003eNo crash-rated barrier function is established.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003ePosition the Controls for Safe and Practical Access\u003c\/h2\u003e\u003cp\u003ePlan the pedestal location around the vehicles and users who will approach it. Check driver reach, the gate’s movement envelope, pedestrian routing and clearance for equipment servicing. A pedestal should not encourage users to lean through a moving gate or stand in a hazardous area. The installed device and its mounting plate determine the actual interface height and position.\u003c\/p\u003e\u003cp\u003eInspect an existing pad and anchors before reusing them. Cracks, loose anchors or impact damage require assessment rather than concealment beneath a new base. Follow the pedestal and access-device instructions for the mounting pattern, cable route and fasteners. A sturdy-looking post does not establish a rated vehicle barrier, and site protection needs should be evaluated separately.\u003c\/p\u003e\u003ch2\u003eSpecifications and Product Identification\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePED42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct\u003c\/td\u003e\n\u003ctd\u003eSingle-height gooseneck pedestal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal height\u003c\/td\u003e\n\u003ctd\u003e42 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003ePad mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePost\u003c\/td\u003e\n\u003ctd\u003e2 × 2-inch square\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePublished construction\u003c\/td\u003e\n\u003ctd\u003e11-gauge steel, black powder-coated finish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eBefore Ordering\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIdentify the access device and verify its mounting pattern.\u003c\/li\u003e\n\u003cli\u003eCheck driver reach, device height and moving-gate clearance.\u003c\/li\u003e\n\u003cli\u003eAssess the pad, anchor layout and cable route.\u003c\/li\u003e\n\u003cli\u003eConfirm supplied hardware and any separate device-mounting adapter.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003ePackage Contents and Separate Requirements\u003c\/h2\u003e\u003cp\u003eThis offer identifies the PED42 pedestal. A keypad, reader, intercom, concrete pad, wiring, anchor set and device-specific adapter are not promised as included. Confirm the current carton and installation drawing before selecting separate mounting hardware. Photographs of a completed entry station illustrate an application and do not make the electronic device part of the pedestal purchase.\u003c\/p\u003e\u003ch2 class=\"safety-warning\"\u003eSafety Warnings — Read Before Installation or Service\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWARNING: Pedestal installation near an active lane exposes workers to vehicles and moving gates. Control traffic and use a qualified installer.\u003c\/li\u003e\n\u003cli\u003eCheck for buried services before any anchoring or site work. Isolate applicable device power before disturbing wiring.\u003c\/li\u003e\n\u003cli\u003eSecure the pedestal using the approved pad and mounting method. Do not use it as a lifting point, gate support or crash barrier.\u003c\/li\u003e\n\u003cli\u003eVerify stable mounting, protected wiring, safe user position and normal access operation before reopening the entrance.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eRelated Products and Important Differences\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-wireless-security-20-keypad-metal\"\u003eKPW250 wireless keypad\u003c\/a\u003e — a documented keypad family for pedestal applications; verify attachment and safe placement.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-wireless-security-20-keypad-plastic-housing\"\u003eLiftMaster plastic-housing wireless keypad\u003c\/a\u003e — compare access-device requirements and mounting compatibility before choosing the entry station.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eIs this the in-ground pedestal?\u003c\/h3\u003e\u003cp\u003eNo. PED42 is identified as a pad-mount model.\u003c\/p\u003e\u003ch3\u003eIs a keypad included?\u003c\/h3\u003e\u003cp\u003eNo. The access device is a separate purchase.\u003c\/p\u003e\u003ch3\u003eDoes 42 inches specify the final keypad height?\u003c\/h3\u003e\u003cp\u003eNot by itself. The mounting arrangement and attached device determine the final user interface position.\u003c\/p\u003e\u003ch3\u003eWill it protect the entry station from a vehicle collision?\u003c\/h3\u003e\u003cp\u003eNo impact rating is claimed. Evaluate vehicle protection separately.\u003c\/p\u003e\u003ch2\u003eNeed Help Confirming the Right Product?\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/garage-doorparts.com\/pages\/contact\"\u003eContact Garage-DoorParts.com before ordering\u003c\/a\u003e. Send the full equipment model, readable part labels and photographs of the installed assembly. Include the dimensions, electrical configuration or accessory details relevant to your project so the listing can be checked against the actual installation.\u003c\/p\u003e","brand":"Controlled Products","offers":[{"title":"Default Title","offer_id":60723289850142,"sku":"PED42","price":220.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0978\/2781\/5710\/files\/ped42.jpg?v=1793244749","url":"https:\/\/garage-doorparts.com\/products\/liftmaster-ped42","provider":"garage-doorparts.com","version":"1.0","type":"link"}