{"product_id":"liftmaster-ma200","title":"LiftMaster MA200 K1 Auxiliary Relay Output Option — Mega Arm","description":"\u003cp\u003e\u003cstrong\u003eThe LiftMaster MA200 is the K1 auxiliary relay output option documented for the Mega Arm barrier-operator control system. It provides the specified relay accessory for approved output and sequencing arrangements, including manufacturer-described coordination with another operator. Match the installed control-board generation and wiring diagram before ordering. The relay option does not replace the main board, supply an independent access controller or create an approved traffic sequence simply by being installed; the connected equipment and operating logic must be configured and tested together.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eCompatibility — Models, Versions and Exclusions\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel or selection point\u003c\/th\u003e\n\u003cth\u003eCompatibility requirement\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDocumented Mega Arm control\u003c\/td\u003e\n\u003ctd\u003eManufacturer manual lists MA200 as the K1 relay option.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Tower \/ Sprint configurations\u003c\/td\u003e\n\u003ctd\u003eVerify the actual board and applicable manual.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSequenced operator arrangement\u003c\/td\u003e\n\u003ctd\u003eRequires compatible connections and the prescribed sequence setup.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOther LiftMaster relay boards\u003c\/td\u003e\n\u003ctd\u003eNo interchangeability from the word relay alone.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety inputs or motor power\u003c\/td\u003e\n\u003ctd\u003eDifferent functions; do not use an auxiliary output as a substitute.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eConfirm the Required Output Behavior Before Installation\u003c\/h2\u003e\u003cp\u003eDecide what the relay must do in the intended installation and compare that requirement with the operator’s documented output behavior. A relay used to signal another operator is part of a larger control sequence. The installer must identify the connected input, its electrical requirements and the expected response when either operator is stopped, faulted or without power.\u003c\/p\u003e\u003cp\u003eThe Mega Arm manual describes specific K1 relay and connector arrangements. Use the instructions for the actual board revision instead of transferring settings from a newer platform. Confirm the relay-contact limits before connecting an external load, and do not assume that the output supplies power to that device. Commission the full sequence with traffic controlled and all required detection and protection operating.\u003c\/p\u003e\u003ch2\u003eSpecifications and Product Identification\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart number\u003c\/td\u003e\n\u003ctd\u003eMA200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent\u003c\/td\u003e\n\u003ctd\u003eK1 auxiliary relay output option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDocumented family\u003c\/td\u003e\n\u003ctd\u003eMega Arm \/ Mega Arm Tower and supported related revisions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eApproved auxiliary relay output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl location\u003c\/td\u003e\n\u003ctd\u003eDocumented K1 arrangement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical selection\u003c\/td\u003e\n\u003ctd\u003eFollow model-specific contact and wiring requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eBefore Ordering\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIdentify the Mega Arm model and installed control board.\u003c\/li\u003e\n\u003cli\u003eConfirm MA200 and the K1 connection in the correct manual.\u003c\/li\u003e\n\u003cli\u003eDefine the intended output function and verify the connected circuit.\u003c\/li\u003e\n\u003cli\u003ePlan sequence, fault-response and safety tests before normal traffic.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003ePackage Contents and Separate Requirements\u003c\/h2\u003e\u003cp\u003eThis offer identifies the MA200 relay option. Confirm the current service package for the relay, connector and any supplied connection pieces. A main board, external operator, loop detector, access reader, wiring run and complete sequencing system are not promised as included. Accessories illustrated together in an application drawing remain separate requirements unless expressly included in the supplier package.\u003c\/p\u003e\u003ch2 class=\"safety-warning\"\u003eSafety Warnings — Read Before Installation or Service\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWARNING: An auxiliary relay can command movement of another gate or barrier. Use a qualified installer and keep people and vehicles clear during service and testing.\u003c\/li\u003e\n\u003cli\u003eDisconnect all relevant power sources, including those on connected equipment, before wiring the relay circuit.\u003c\/li\u003e\n\u003cli\u003eDo not bypass interlocks, entrapment protection or detection to make an unverified sequence operate. Match contact and load requirements to the manual.\u003c\/li\u003e\n\u003cli\u003eTest the complete sequence and fault response, restore covers and maintain a separate pedestrian route before reopening the lane.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eRelated Products and Important Differences\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-wireless-security-20-keypad-metal\"\u003eKPW250 wireless keypad\u003c\/a\u003e — a separate access input for compatible receivers; not a relay or a complete sequencing controller.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/loop-detector\"\u003eLOOPDETLM loop detector\u003c\/a\u003e — a different detection component; confirm the exact control platform before considering it for an installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eIs MA200 a main control board?\u003c\/h3\u003e\u003cp\u003eNo. It is the optional K1 relay accessory.\u003c\/p\u003e\u003ch3\u003eDoes it power another gate motor directly?\u003c\/h3\u003e\u003cp\u003eDo not assume that use. Follow the documented signal and contact ratings for the connected circuit.\u003c\/p\u003e\u003ch3\u003eWill it fit every Mega-series revision?\u003c\/h3\u003e\u003cp\u003eConfirm the actual control board and service documentation.\u003c\/p\u003e\u003ch3\u003eDoes installing it finish a sequencing project?\u003c\/h3\u003e\u003cp\u003eNo. Compatible wiring, settings, detection and full system tests are still required.\u003c\/p\u003e\u003ch2\u003eNeed Help Confirming the Right Product?\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/garage-doorparts.com\/pages\/contact\"\u003eContact Garage-DoorParts.com before ordering\u003c\/a\u003e. Send the full equipment model, readable part labels and photographs of the installed assembly. Include the dimensions, electrical configuration or accessory details relevant to your project so the listing can be checked against the actual installation.\u003c\/p\u003e","brand":"Controlled Products","offers":[{"title":"Default Title","offer_id":60723281821982,"sku":"MA200","price":46.58,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0978\/2781\/5710\/files\/ma200.png?v=1793244741","url":"https:\/\/garage-doorparts.com\/products\/liftmaster-ma200","provider":"garage-doorparts.com","version":"1.0","type":"link"}