{"product_id":"liftmaster-k94-38062-2","title":"LiftMaster K94-38062-2 Power-Board Identification Resistor — 1 HP, Three Phase","description":"\u003cp\u003e\u003cstrong\u003eThe LiftMaster K94-38062-2 is the power-board identification resistor specified for the documented 1 HP three-phase slide gate-operator configuration. The manufacturer separately lists a 575V 1 HP identification reference, so horsepower and phase alone are not sufficient selection criteria. Match the complete operator electrical arrangement and power-board service information before ordering this configuration-dependent component. Select the replacement by the complete part number and the installed equipment configuration. A similar photograph or a shared LiftMaster brand name does not establish interchangeability. Confirm the applicable service drawing before ordering so the repair addresses the correct component and its related mounting, connection and operating requirements.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eCompatibility — Models, Versions and Exclusions\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel or selection point\u003c\/th\u003e\n\u003cth\u003eCompatibility requirement\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproved 1 HP three-phase configuration\u003c\/td\u003e\n\u003ctd\u003eConfirm the exact service reference and supply group.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e575V 1 HP\u003c\/td\u003e\n\u003ctd\u003eA separately identified resistor reference must be checked.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\/2 HP \/ 2 HP\u003c\/td\u003e\n\u003ctd\u003eDifferent identification selections; not equivalents.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle phase\u003c\/td\u003e\n\u003ctd\u003eNo interchangeability is established.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eIdentify the Assembly and Plan the Repair\u003c\/h2\u003e\u003cp\u003eThe identification component must correspond to the actual motor and power-board arrangement. Record the operator nameplate, supply, motor rating and board reference before replacing it. Do not fit another identification part to make the controller recognize a different horsepower or conceal a drive fault.\u003c\/p\u003e\u003cp\u003eThe service list identifies the intended configuration but does not provide an independently verified resistance, tolerance or wattage for selecting a loose electronic substitute. Use the approved exact part and inspect related connectors or wiring for damage. A resistor-only repair does not establish that a damaged power board is serviceable.\u003c\/p\u003e\u003cp\u003eAn electrical symptom does not identify the failed component by itself. Have qualified service personnel inspect the supply, wiring, connections and equipment condition before replacing parts. Record existing labels and terminal references with power safely isolated. A replacement should restore the documented circuit arrangement; it should not be used to change operating voltage, defeat a protective function or compensate for a mechanical load that the equipment cannot safely move.\u003c\/p\u003e\u003ch2\u003eSpecifications and Product Identification\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrdering reference\u003c\/td\u003e\n\u003ctd\u003eK94-38062-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003ePower-board configuration identification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorsepower context\u003c\/td\u003e\n\u003ctd\u003e1 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eThree phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeparate 575V reference\u003c\/td\u003e\n\u003ctd\u003eK94-38062-5 in the documented service table\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance value\u003c\/td\u003e\n\u003ctd\u003eNo unverified ohmic value is claimed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eBefore Ordering\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eRead the motor and operator electrical nameplates.\u003c\/li\u003e\n\u003cli\u003eVerify 1 HP, three phase and the actual supply group.\u003c\/li\u003e\n\u003cli\u003eMatch K94-38062-2 in the applicable board service table.\u003c\/li\u003e\n\u003cli\u003eInspect the connector and underlying cause of the fault.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003ePackage Contents and Separate Requirements\u003c\/h2\u003e\u003cp\u003eThis offer identifies the power-board identification resistor service item. Confirm current connector or lead pieces supplied. A power board, motor, voltage-conversion kit and complete operator are not established as included; changing the resistor does not establish an approved change to motor capacity or supply configuration.\u003c\/p\u003e\u003ch2 class=\"safety-warning\"\u003eSafety Warnings — Read Before Installation or Service\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWARNING: Electrical service can expose hazardous voltage and moving equipment. Use qualified service personnel and electrical personnel where required.\u003c\/li\u003e\n\u003cli\u003eDisconnect every applicable mains, battery and auxiliary supply before work. Follow the equipment instructions for stored energy and safe isolation.\u003c\/li\u003e\n\u003cli\u003eDo not bypass grounding, overload protection, monitored safety devices or fire-control functions to make the equipment operate. Diagnose the underlying fault.\u003c\/li\u003e\n\u003cli\u003eRestore covers and wiring protection, then complete the model-specific functional and safety checks before returning the installation to normal use.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eRelated Products and Important Differences\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-photocell-kit-indoor-only-for-30-wide-openings\"\u003eCPS-U monitored photo eyes\u003c\/a\u003e — separate protection devices for approved commercial-door controls; match the operator and environment.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-extended-duty-trolley-operator\"\u003eTDC12X1BMC MAXUM trolley operator\u003c\/a\u003e — a complete-operator comparison, not evidence that this legacy service part fits MAXUM.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eCan it be used for every 1 HP three-phase model?\u003c\/h3\u003e\u003cp\u003eNo. The exact supply and service configuration must match; the documented table identifies a separate 575V reference.\u003c\/p\u003e\u003ch3\u003eIs the resistor value the same as 1 HP?\u003c\/h3\u003e\u003cp\u003eNo. Horsepower is an equipment-configuration designation, not an ohmic value.\u003c\/p\u003e\u003ch3\u003eDoes it include the power board?\u003c\/h3\u003e\u003cp\u003eNo complete board is identified. It is the configuration resistor service item.\u003c\/p\u003e\u003ch3\u003eCan I use it to increase operator capacity?\u003c\/h3\u003e\u003cp\u003eNo. An identification component does not increase motor capacity or authorize a different equipment configuration.\u003c\/p\u003e\u003ch2\u003eNeed Help Confirming the Right Product?\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/garage-doorparts.com\/pages\/contact\"\u003eContact Garage-DoorParts.com before ordering\u003c\/a\u003e. Send the full equipment model, readable part labels and photographs of the installed assembly. Include the dimensions, electrical configuration or accessory details relevant to your project so the listing can be checked against the actual installation.\u003c\/p\u003e","brand":"Controlled Products","offers":[{"title":"Default Title","offer_id":60730225197342,"sku":"K94-38062-2","price":18.83,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0978\/2781\/5710\/files\/k94-38062-2.jpg?v=1793254764","url":"https:\/\/garage-doorparts.com\/products\/liftmaster-k94-38062-2","provider":"garage-doorparts.com","version":"1.0","type":"link"}