{"product_id":"liftmaster-k94-35152","title":"LiftMaster K94-35152 Piezo Alarm — Documented Gate Operators","description":"\u003cp\u003e\u003cstrong\u003eThe LiftMaster K94-35152 is the piezo-alarm service component identified in documented LiftMaster gate-operator parts information, including CSL24U and CSL24UL configurations. It provides the audible output commanded by the compatible control system and is separate from the sensors and circuitry that detect operating conditions. Match the complete model, existing alarm and connection before ordering. Replacing the sounder should follow diagnosis of both the alarm circuit and any fault causing it to sound; silencing an alarm does not correct an unsafe or malfunctioning gate.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eCompatibility — Models, Versions and Exclusions\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel or selection point\u003c\/th\u003e\n\u003cth\u003eCompatibility requirement\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCSL24U \/ CSL24UL documented arrangements\u003c\/td\u003e\n\u003ctd\u003eMatch the alarm reference in the correct parts list.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOther listed gate operators\u003c\/td\u003e\n\u003ctd\u003eVerify the same reference and installed connection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK94-36411 or other alarm references\u003c\/td\u003e\n\u003ctd\u003eDo not substitute solely because both are piezo sounders.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEntrapment sensors\u003c\/td\u003e\n\u003ctd\u003eSeparate components; the alarm does not detect an obstruction by itself.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire or security alarm systems\u003c\/td\u003e\n\u003ctd\u003eNot established applications for this operator service part.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eDiagnose the Alarm Circuit and the Underlying Condition\u003c\/h2\u003e\u003cp\u003eIf an alarm does not sound when required, the fault may involve the sounder, its wiring or the control output. If it sounds repeatedly, investigate the condition that triggers it rather than disconnecting the alarm. Record diagnostic information and have a qualified technician inspect the connected system. A new sounder cannot repair a damaged safety input or a gate that repeatedly binds.\u003c\/p\u003e\u003cp\u003eCompare the original alarm and connection with the model-specific repair drawing before removal. Preserve the intended mounting and avoid blocking or covering the sound outlet. Do not connect an unidentified sounder to a convenient power terminal or assume that every alarm uses the same supply. After service, test the alarm using the prescribed procedure and verify the operator’s separate movement and protection functions.\u003c\/p\u003e\u003ch2\u003eSpecifications and Product Identification\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart number\u003c\/td\u003e\n\u003ctd\u003eK94-35152\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct\u003c\/td\u003e\n\u003ctd\u003ePiezo alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVerified model examples\u003c\/td\u003e\n\u003ctd\u003eCSL24U \/ CSL24UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eAudible operator indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical connection\u003c\/td\u003e\n\u003ctd\u003eUse exact model wiring requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound level\u003c\/td\u003e\n\u003ctd\u003eNo unverified decibel rating specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eBefore Ordering\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eRecord the complete operator model and existing alarm number.\u003c\/li\u003e\n\u003cli\u003eCheck the wiring, connector and control output.\u003c\/li\u003e\n\u003cli\u003eIdentify any underlying condition that repeatedly activates the alarm.\u003c\/li\u003e\n\u003cli\u003eConfirm the current package and model-specific functional test.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003ePackage Contents and Separate Requirements\u003c\/h2\u003e\u003cp\u003eThis offer identifies the K94-35152 piezo alarm. A main control board, safety sensor, reset switch, full harness and complete operator are not promised as included. Confirm the current carton for any alarm-specific lead or mounting pieces. The alarm’s presence in a parts diagram does not mean it includes the electronics that decide when to sound or the separate devices required to protect the entrance.\u003c\/p\u003e\u003ch2 class=\"safety-warning\"\u003eSafety Warnings — Read Before Installation or Service\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWARNING: Do not disable or muffle an operator alarm to conceal a fault. Have the cause assessed by a qualified gate technician.\u003c\/li\u003e\n\u003cli\u003eIsolate applicable power and secure the gate before replacing the alarm or disturbing wiring.\u003c\/li\u003e\n\u003cli\u003eMatch the prescribed electrical connection. Never bypass safety inputs or remove required protection because a sounder has been replaced.\u003c\/li\u003e\n\u003cli\u003eTest audible operation, normal gate travel and all required safety responses before returning the entrance to service.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eRelated Products and Important Differences\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-lmrrul-monitored-retro-reflective-photo-eye\"\u003eLMRRUL monitored photo eye\u003c\/a\u003e — a separate protection option only where the exact operator and control revision approve it; not a universal legacy retrofit.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-lmwekitu-monitored-wireless-edge-kit-for-gate-operators\"\u003eLMWEKITU monitored wireless edge kit\u003c\/a\u003e — a separate edge communication system for approved controls and resistive edges; not a replacement for this mechanical or electrical service part.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eDoes the alarm detect obstacles by itself?\u003c\/h3\u003e\u003cp\u003eNo. It provides audible output under the compatible operator’s control.\u003c\/p\u003e\u003ch3\u003eCan I disconnect it if it keeps sounding?\u003c\/h3\u003e\u003cp\u003eDo not conceal the fault; diagnose the trigger and repair the system.\u003c\/p\u003e\u003ch3\u003eIs every LiftMaster piezo alarm interchangeable?\u003c\/h3\u003e\u003cp\u003eNo. Match the full reference and connection requirements.\u003c\/p\u003e\u003ch3\u003eDoes it include a control board?\u003c\/h3\u003e\u003cp\u003eNo control board is promised with this alarm offer.\u003c\/p\u003e\u003ch2\u003eNeed Help Confirming the Right Product?\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/garage-doorparts.com\/pages\/contact\"\u003eContact Garage-DoorParts.com before ordering\u003c\/a\u003e. Send the full equipment model, readable part labels and photographs of the installed assembly. Include the dimensions, electrical configuration or accessory details relevant to your project so the listing can be checked against the actual installation.\u003c\/p\u003e","brand":"Controlled Products","offers":[{"title":"Default Title","offer_id":60723421905182,"sku":"K94-35152","price":84.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0978\/2781\/5710\/files\/k94-35152.jpg?v=1793244899","url":"https:\/\/garage-doorparts.com\/products\/liftmaster-k94-35152","provider":"garage-doorparts.com","version":"1.0","type":"link"}