{"product_id":"liftmaster-k71-d1ph","title":"LiftMaster K71-D1PH Single-Phase Drum Brake Kit — Logic 5 T, J and H","description":"\u003cp\u003e\u003cstrong\u003eThe LiftMaster K71-D1PH is the single-phase drum-brake kit covered by the manufacturer’s Logic 5 T, J and H installation instructions. It supplies a coordinated brake-repair or approved brake-addition package rather than an individual solenoid. The instructions distinguish replacement of an existing brake from adding a brake to eligible 1\/3- or 1\/2-horsepower operators. Match the operator, brake arrangement and electrical circuit before ordering; the source’s 120V designation is not permission to connect the kit using supply voltage alone.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eCompatibility — Models, Versions and Exclusions\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel or selection point\u003c\/th\u003e\n\u003cth\u003eCompatibility requirement\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eExisting brake on documented Logic 5 T \/ J \/ H\u003c\/td\u003e\n\u003ctd\u003eConfirm the kit and procedure for the installed arrangement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdding a brake\u003c\/td\u003e\n\u003ctd\u003eUse only the horsepower\/model applications approved by the instructions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK71-D3PH \/ K71-D575-1\u003c\/td\u003e\n\u003ctd\u003eDifferent electrical kit references in the shared instructions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndividual brake solenoid\u003c\/td\u003e\n\u003ctd\u003eDifferent repair scope; not the complete drum-brake kit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOther generations or brake designs\u003c\/td\u003e\n\u003ctd\u003eNo blanket substitution based on motor phase alone.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eDistinguish a Brake Replacement from a Brake Addition\u003c\/h2\u003e\u003cp\u003eBefore purchasing, establish whether the operator already has the documented brake or needs an approved addition. These are different service situations. Record the full model, horsepower, electrical data and existing mechanism. A door that drifts or stops inconsistently also needs a mechanical inspection; the brake should not be used to hide an unbalanced door or defective counterbalance hardware.\u003c\/p\u003e\u003cp\u003eThe manufacturer procedure addresses the brake drum, solenoid assembly, release cable and wiring as a coordinated installation. Have a technician check clearances and alignment against that procedure. Do not transfer wiring assumptions from a three-phase kit or a different brake design. After installation, verify the intended release and stopping behavior and restore the operator guards before testing normal door travel.\u003c\/p\u003e\u003ch2\u003eSpecifications and Product Identification\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart number\u003c\/td\u003e\n\u003ctd\u003eK71-D1PH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct\u003c\/td\u003e\n\u003ctd\u003eDrum brake kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical family\u003c\/td\u003e\n\u003ctd\u003eSingle phase; verify brake circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSource voltage designation\u003c\/td\u003e\n\u003ctd\u003e120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstruction platform\u003c\/td\u003e\n\u003ctd\u003eLogic 5 T \/ J \/ H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrake-addition restriction\u003c\/td\u003e\n\u003ctd\u003eManufacturer specifies eligible 1\/3 HP and 1\/2 HP operators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eBefore Ordering\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eRecord operator model, horsepower and brake arrangement.\u003c\/li\u003e\n\u003cli\u003eIdentify replacement versus approved brake-addition work.\u003c\/li\u003e\n\u003cli\u003eMatch the actual brake circuit to the single-phase kit instructions.\u003c\/li\u003e\n\u003cli\u003eCheck all supplied components and any separately required service parts.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003ePackage Contents and Separate Requirements\u003c\/h2\u003e\u003cp\u003eThe manufacturer inventory identifies the solenoid brake assembly, brake-release cable kit, brake drum, cable sleeve, threadlocker, wire-harness kit, harness conduit, two cable ties and four flat washers. Verify the current carton against its supplied instructions. A motor, gearbox, complete operator and door counterbalance components are not included in this brake-kit scope. Do not confuse this inventory with an individual replacement solenoid.\u003c\/p\u003e\u003ch2 class=\"safety-warning\"\u003eSafety Warnings — Read Before Installation or Service\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWARNING: Brake work can allow the door to move unexpectedly. A trained commercial-door technician must secure the door before disturbing the brake.\u003c\/li\u003e\n\u003cli\u003eDisconnect all power and any backup source before mechanical or electrical work. Confirm circuit requirements from the manufacturer diagram.\u003c\/li\u003e\n\u003cli\u003eDo not bypass the brake or use it to compensate for damaged springs, cables or an unbalanced door.\u003c\/li\u003e\n\u003cli\u003eCheck release operation, stopping behavior, travel and required safety devices after installation and before returning the door to service.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eRelated Products and Important Differences\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-brake-solenoid-120v\"\u003e120V brake solenoid\u003c\/a\u003e — an individual component comparison, not the complete K71-D1PH inventory.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-photocell-kit-indoor-only-for-30-wide-openings\"\u003eCPS-U monitored photo eyes\u003c\/a\u003e — separate protection devices only for approved commercial-operator configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eIs this only a solenoid?\u003c\/h3\u003e\u003cp\u003eNo. The documented kit contains the drum, release and installation components as well as the solenoid assembly.\u003c\/p\u003e\u003ch3\u003eCan it add a brake to every single-phase operator?\u003c\/h3\u003e\u003cp\u003eNo. Follow the specified model and horsepower restrictions.\u003c\/p\u003e\u003ch3\u003eCan I use the three-phase wiring instructions?\u003c\/h3\u003e\u003cp\u003eNo. Use the correct single-phase kit and operator circuit information.\u003c\/p\u003e\u003ch3\u003eDoes a new brake repair a door balance problem?\u003c\/h3\u003e\u003cp\u003eNo. The door and counterbalance need separate diagnosis.\u003c\/p\u003e\u003ch2\u003eNeed Help Confirming the Right Product?\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/garage-doorparts.com\/pages\/contact\"\u003eContact Garage-DoorParts.com before ordering\u003c\/a\u003e. Send the full equipment model, readable part labels and photographs of the installed assembly. Include the dimensions, electrical configuration or accessory details relevant to your project so the listing can be checked against the actual installation.\u003c\/p\u003e","brand":"Controlled Products","offers":[{"title":"Default Title","offer_id":60723265700126,"sku":"K71-D1PH","price":455.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0978\/2781\/5710\/files\/k71-d1ph.jpg?v=1793244715","url":"https:\/\/garage-doorparts.com\/products\/liftmaster-k71-d1ph","provider":"garage-doorparts.com","version":"1.0","type":"link"}