{"product_id":"liftmaster-k41-0381-000","title":"LiftMaster K41-0381-000 Toroidal Transformer — MAXUM 700, 120\/240VAC","description":"\u003cp\u003e\u003cstrong\u003eThe LiftMaster K41-0381-000 is the toroidal-transformer service reference identified for documented MAXUM 700 commercial-door operator configurations using the 120\/240VAC version. It must be distinguished from the 700-series480VAC transformer and from the1200- and2200-series transformer references. The700 designation identifies the operator service family, not a transformer output wattage. Match the full operator and delivered electrical diagram before ordering. This is an internal replacement component, not a complete power-conversion kit for changing the building supply or upgrading an operator’s capacity.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eCompatibility — Models, Versions and Exclusions\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel or selection point\u003c\/th\u003e\n\u003cth\u003eCompatibility requirement\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAXUM 700 arrangements listing this reference\u003c\/td\u003e\n\u003ctd\u003eMatch the complete model and supply version.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e700-series480VAC\u003c\/td\u003e\n\u003ctd\u003eDifferent transformer reference.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAXUM1200 \/2200\u003c\/td\u003e\n\u003ctd\u003eSeparate transformer families.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e208V transformer kits\u003c\/td\u003e\n\u003ctd\u003eDifferent accessories; no tap or conversion inferred.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor, gearbox and encoder\u003c\/td\u003e\n\u003ctd\u003eSeparate assemblies; this item is the transformer.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eDiagnose the Power Path Before Replacing the Transformer\u003c\/h2\u003e\u003cp\u003eLoss of operator power can involve the incoming circuit, transformer connections, protective components or downstream electronics. Have qualified personnel identify the failed stage rather than replacing the transformer solely because the door does not move. Preserve any diagnostic information and inspect for damaged wiring or moisture. A new transformer cannot correct a shorted load or a continuing supply fault.\u003c\/p\u003e\u003cp\u003ePhotograph the existing label and connections before removal. Compare the mounting and lead arrangement with the correct MAXUM operator drawing, then use the supplied replacement instructions. Keep the transformer, main board and rectifier distinct when ordering parts. Do not guess voltage taps, reuse damaged connectors or treat this component as a complete change of the operator’s electrical supply configuration.\u003c\/p\u003e\u003ch2\u003eSpecifications and Product Identification\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart number\u003c\/td\u003e\n\u003ctd\u003eK41-0381-000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct\u003c\/td\u003e\n\u003ctd\u003eToroidal transformer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform\u003c\/td\u003e\n\u003ctd\u003eDocumented MAXUM 700 configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput designation\u003c\/td\u003e\n\u003ctd\u003e120\/240VAC version\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDifferent version\u003c\/td\u003e\n\u003ctd\u003eK41-0382-000 \/700,480VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput and connections\u003c\/td\u003e\n\u003ctd\u003eMatch current nameplate and exact operator diagram\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eBefore Ordering\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eRecord full MAXUM model and supply configuration.\u003c\/li\u003e\n\u003cli\u003eConfirm700 family and120\/240VAC transformer version.\u003c\/li\u003e\n\u003cli\u003eMatch nameplate, terminals and mounting arrangement.\u003c\/li\u003e\n\u003cli\u003eDiagnose load and wiring faults before replacing the transformer.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003ePackage Contents and Separate Requirements\u003c\/h2\u003e\u003cp\u003eThis offer identifies the K41-0381-000 toroidal transformer. A motor, gearbox, encoder, main board, rectifier, control enclosure and external supply-conversion kit are not promised as included. Confirm the current transformer package for mounting and connection pieces. Some catalog headings can group several service parts together; the exact reference here identifies the transformer, not a combined motor-and-encoder assembly. Establish any additional damaged components through the model-specific repair diagram.\u003c\/p\u003e\u003ch2 class=\"safety-warning\"\u003eSafety Warnings — Read Before Installation or Service\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWARNING: A moving commercial door and exposed transformer and electrical controls can cause serious injury or death. Have a trained door-systems technician perform installation and service.\u003c\/li\u003e\n\u003cli\u003eDisconnect mains power and any battery backup before mechanical work or wiring. Secure the door against unexpected movement as directed by its manufacturer.\u003c\/li\u003e\n\u003cli\u003eDo not work on springs, cables or counterbalance components without appropriate training. Never bypass safety sensors or increase force to overcome binding.\u003c\/li\u003e\n\u003cli\u003eRestore guards and complete the model-specific travel, reversal and protection-device tests before returning the door to normal operation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eRelated Products and Important Differences\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-photocell-kit-indoor-only-for-30-wide-openings\"\u003eCPS-U monitored photo eyes\u003c\/a\u003e — separate protection devices for approved commercial-door controls; match the operator and environment.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-extended-duty-trolley-operator\"\u003eTDC12X1BMC MAXUM trolley operator\u003c\/a\u003e — a complete-operator comparison, not evidence that this legacy service part fits MAXUM.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eDoes700 mean700 watts output?\u003c\/h3\u003e\u003cp\u003eNo. It is the MAXUM operator-family designation in the parts list.\u003c\/p\u003e\u003ch3\u003eIs this the480V version?\u003c\/h3\u003e\u003cp\u003eNo. That is separately identified as K41-0382-000 for the 700 family.\u003c\/p\u003e\u003ch3\u003eIs the motor included?\u003c\/h3\u003e\u003cp\u003eNo. This offer identifies a transformer.\u003c\/p\u003e\u003ch3\u003eCan it change an operator’s rated capacity?\u003c\/h3\u003e\u003cp\u003eNo capacity upgrade or supply conversion is established.\u003c\/p\u003e\u003ch2\u003eNeed Help Confirming the Right Product?\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/garage-doorparts.com\/pages\/contact\"\u003eContact Garage-DoorParts.com before ordering\u003c\/a\u003e. Send the full equipment model, readable part labels and photographs of the installed assembly. Include the dimensions, electrical configuration or accessory details relevant to your project so the listing can be checked against the actual installation.\u003c\/p\u003e","brand":"Controlled Products","offers":[{"title":"Default Title","offer_id":60723496157470,"sku":"K41-0381-000","price":208.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0978\/2781\/5710\/files\/k41-0381-000.png?v=1793244989","url":"https:\/\/garage-doorparts.com\/products\/liftmaster-k41-0381-000","provider":"garage-doorparts.com","version":"1.0","type":"link"}