{"product_id":"liftmaster-k41-0378-000","title":"LiftMaster K41-0378-000 24V DC Motor, Gearbox and Encoder Assembly — T1200","description":"\u003cp\u003e\u003cstrong\u003eThe LiftMaster K41-0378-000 identifies the combined 24V DC motor, gearbox and encoder service assembly designated T1200. It addresses the motor and its associated drive and position-feedback components as an assembly, rather than a bare replacement motor. Confirm the complete operator service reference before selecting it for a commercial trolley installation. Select the replacement by the complete part number and the installed equipment configuration. A similar photograph or a shared LiftMaster brand name does not establish interchangeability. Confirm the applicable service drawing before ordering so the repair addresses the correct component and its related mounting, connection and operating requirements.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eCompatibility — Models, Versions and Exclusions\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel or selection point\u003c\/th\u003e\n\u003cth\u003eCompatibility requirement\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eT1200 service assembly\u003c\/td\u003e\n\u003ctd\u003eUse where the applicable operator parts documentation specifies K41-0378-000.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT700 assembly\u003c\/td\u003e\n\u003ctd\u003eA different motor assembly reference; do not select by appearance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJH1200 assembly\u003c\/td\u003e\n\u003ctd\u003eThe jackshaft\/hoist designation does not establish interchangeability.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtended-duty trolley versions\u003c\/td\u003e\n\u003ctd\u003eCheck their separate motor reference and complete model suffix.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eIdentify the Assembly and Plan the Repair\u003c\/h2\u003e\u003cp\u003eThe gearbox ratio, mechanical mounting and encoder arrangement must remain appropriate for the installed operator. A motor that turns is not evidence that its feedback and gearing match the controller. Have the technician identify whether the fault lies in the motor assembly, the supply, the wiring or a mechanical load before choosing the repair.\u003c\/p\u003e\u003cp\u003eThe 24V DC identification describes the motor assembly; it does not authorize connecting the commercial operator to an arbitrary 24V supply. The operator has its own input-power and control requirements. Record the equipment nameplate, existing assembly label, connector arrangement and drive configuration so the supplier can check the complete service match.\u003c\/p\u003e\u003cp\u003eAn electrical symptom does not identify the failed component by itself. Have qualified service personnel inspect the supply, wiring, connections and equipment condition before replacing parts. Record existing labels and terminal references with power safely isolated. A replacement should restore the documented circuit arrangement; it should not be used to change operating voltage, defeat a protective function or compensate for a mechanical load that the equipment cannot safely move.\u003c\/p\u003e\u003ch2\u003eSpecifications and Product Identification\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrdering reference\u003c\/td\u003e\n\u003ctd\u003eK41-0378-000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssembly designation\u003c\/td\u003e\n\u003ctd\u003eT1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor designation\u003c\/td\u003e\n\u003ctd\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponents identified\u003c\/td\u003e\n\u003ctd\u003eMotor, gearbox and encoder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eExact commercial trolley service configuration must match\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eBefore Ordering\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eRecord the full operator model and service revision.\u003c\/li\u003e\n\u003cli\u003eMatch the T1200 assembly designation and complete ordering reference.\u003c\/li\u003e\n\u003cli\u003eInspect the drive and door for binding before condemning the motor.\u003c\/li\u003e\n\u003cli\u003eConfirm connector, mounting and commissioning requirements with the service documentation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003ePackage Contents and Separate Requirements\u003c\/h2\u003e\u003cp\u003eThe ordering reference identifies the motor, gearbox and encoder assembly. Do not assume that the main control board, power supply, rail, trolley, chain or complete operator is included. Confirm the current kit inventory, any separately required mounting parts and the instructions supplied with the replacement.\u003c\/p\u003e\u003ch2 class=\"safety-warning\"\u003eSafety Warnings — Read Before Installation or Service\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWARNING: Electrical service can expose hazardous voltage and moving equipment. Use qualified service personnel and electrical personnel where required.\u003c\/li\u003e\n\u003cli\u003eDisconnect every applicable mains, battery and auxiliary supply before work. Follow the equipment instructions for stored energy and safe isolation.\u003c\/li\u003e\n\u003cli\u003eDo not bypass grounding, overload protection, monitored safety devices or fire-control functions to make the equipment operate. Diagnose the underlying fault.\u003c\/li\u003e\n\u003cli\u003eRestore covers and wiring protection, then complete the model-specific functional and safety checks before returning the installation to normal use.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eRelated Products and Important Differences\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-photocell-kit-indoor-only-for-30-wide-openings\"\u003eCPS-U monitored photo eyes\u003c\/a\u003e — separate protection devices for approved commercial-door controls; match the operator and environment.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-extended-duty-trolley-operator\"\u003eTDC12X1BMC MAXUM trolley operator\u003c\/a\u003e — a complete-operator comparison, not evidence that this legacy service part fits MAXUM.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eIs this a bare motor?\u003c\/h3\u003e\u003cp\u003eNo. The manufacturer identifies a combined motor, gearbox and encoder assembly, so compare the entire service arrangement rather than motor size alone.\u003c\/p\u003e\u003ch3\u003eDoes 24V DC describe the building supply?\u003c\/h3\u003e\u003cp\u003eNo. Follow the complete operator nameplate and installation instructions for its supply; the motor designation is a separate specification.\u003c\/p\u003e\u003ch3\u003eCan it replace the T700 version?\u003c\/h3\u003e\u003cp\u003eDo not assume that. Different assembly references require confirmation against the exact operator parts list.\u003c\/p\u003e\u003ch3\u003eWill a new motor fix excessive door resistance?\u003c\/h3\u003e\u003cp\u003eIt will not repair a binding or unbalanced door. Have the door and drive condition checked before installation and final testing.\u003c\/p\u003e\u003ch2\u003eNeed Help Confirming the Right Product?\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/garage-doorparts.com\/pages\/contact\"\u003eContact Garage-DoorParts.com before ordering\u003c\/a\u003e. Send the full equipment model, readable part labels and photographs of the installed assembly. Include the dimensions, electrical configuration or accessory details relevant to your project so the listing can be checked against the actual installation.\u003c\/p\u003e","brand":"Controlled Products","offers":[{"title":"Default Title","offer_id":60723915227422,"sku":"K41-0378-000","price":1661.61,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0978\/2781\/5710\/files\/k41-0378-000.png?v=1793245304","url":"https:\/\/garage-doorparts.com\/products\/liftmaster-k41-0378-000","provider":"garage-doorparts.com","version":"1.0","type":"link"}