{"product_id":"liftmaster-k29-10338","title":"LiftMaster K29-10338 Motor Capacitor — 70 µF, 230V, 50\/60Hz","description":"\u003cp\u003e\u003cstrong\u003eThe LiftMaster K29-10338 is a motor-capacitor service part specified at 70 microfarads, 230V and 50\/60Hz in documented medium-duty commercial-door operator parts information. The 70 MFD notation means 70 µF, not a motor horsepower rating. Match the original capacitor reference, electrical markings, terminals and mounting before ordering. The capacitor rating must not be mistaken for the operator input-supply requirement, and a motor that hums or fails to start still needs diagnosis before this component is selected as the repair.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eCompatibility — Models, Versions and Exclusions\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel or selection point\u003c\/th\u003e\n\u003cth\u003eCompatibility requirement\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMJ configurations listing 29-10338\u003c\/td\u003e\n\u003ctd\u003eMatch the complete model and installed capacitor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOther documented medium-duty operators\u003c\/td\u003e\n\u003ctd\u003eRequire the same manufacturer service reference.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDifferent capacitance values\u003c\/td\u003e\n\u003ctd\u003eNot a substitute based on similar physical size.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V operator input\u003c\/td\u003e\n\u003ctd\u003eNot established by the capacitor voltage marking.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQ027 and other gate capacitors\u003c\/td\u003e\n\u003ctd\u003eDifferent references and ratings; do not interchange by appearance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eConfirm the Capacitor and Diagnose the Starting Circuit\u003c\/h2\u003e\u003cp\u003ePhotograph the original label before removal and compare the capacitor with the operator repair list. Similar cylindrical components may have different capacitance, terminal arrangements and mounting dimensions. Preserve the specified electrical characteristics; choosing a larger value is not a way to increase motor power or overcome a difficult door. If the original label is unreadable, use the exact operator and motor references to identify the required part.\u003c\/p\u003e\u003cp\u003eA starting problem may also involve supply voltage, wiring, relay contacts, motor damage or a mechanically restricted door. Have a qualified technician inspect those conditions before replacing the capacitor. A visibly damaged component may be only part of the problem. After the repair, restore the enclosure and verify starting, stopping and the required safety functions under the manufacturer procedure.\u003c\/p\u003e\u003ch2\u003eSpecifications and Product Identification\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart number\u003c\/td\u003e\n\u003ctd\u003eK29-10338 \/ 29-10338\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent\u003c\/td\u003e\n\u003ctd\u003eMotor capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e70 µF \/ 70 MFD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage designation\u003c\/td\u003e\n\u003ctd\u003e230V capacitor rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDocumented application\u003c\/td\u003e\n\u003ctd\u003eMedium-duty MJ parts information; verify exact revision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eBefore Ordering\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eRecord the operator model, motor data and capacitor reference.\u003c\/li\u003e\n\u003cli\u003eConfirm 70 µF, 230V and 50\/60Hz against the original specification.\u003c\/li\u003e\n\u003cli\u003eMatch terminals, mounting and physical clearance.\u003c\/li\u003e\n\u003cli\u003eHave the starting circuit and door movement assessed before ordering.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003ePackage Contents and Separate Requirements\u003c\/h2\u003e\u003cp\u003eThis listing identifies the K29-10338 motor capacitor. A motor, mounting bracket, relay, wiring harness and complete operator are not promised as included. Confirm any capacitor-specific fastening pieces in the current package. The parts list may show several electrical components together without bundling them into this item. If heat or terminal damage is present, have the associated wiring assessed rather than assuming a capacitor-only order covers the entire repair.\u003c\/p\u003e\u003ch2 class=\"safety-warning\"\u003eSafety Warnings — Read Before Installation or Service\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWARNING: Capacitors can retain hazardous electrical energy after power is disconnected. Have a qualified technician isolate, verify and safely service the circuit.\u003c\/li\u003e\n\u003cli\u003eDisconnect all applicable power sources before opening the operator. Do not touch capacitor terminals or attempt an improvised discharge.\u003c\/li\u003e\n\u003cli\u003eUse the specified capacitance, voltage rating and connection arrangement. Never bypass protection or alter wiring to accommodate a mismatched component.\u003c\/li\u003e\n\u003cli\u003eSecure the door, restore covers and complete the model-specific travel and safety tests before normal operation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eRelated Products and Important Differences\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-photocell-kit-indoor-only-for-30-wide-openings\"\u003eCPS-U monitored photo eyes\u003c\/a\u003e — separate protection devices for approved commercial-door controls; match the operator and environment.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-extended-duty-trolley-operator\"\u003eTDC12X1BMC MAXUM trolley operator\u003c\/a\u003e — a complete-operator comparison, not evidence that this legacy service part fits MAXUM.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eDoes 70 MFD mean 70 microfarads?\u003c\/h3\u003e\u003cp\u003eYes. The listing uses MFD for the 70 µF capacitance value.\u003c\/p\u003e\u003ch3\u003eDoes 230V mean my operator must use 230V input?\u003c\/h3\u003e\u003cp\u003eNo. Capacitor rating and operator supply requirements are different specifications.\u003c\/p\u003e\u003ch3\u003eWill this fix every humming motor?\u003c\/h3\u003e\u003cp\u003eNo. The supply, controls, motor and mechanical load need diagnosis.\u003c\/p\u003e\u003ch3\u003eIs it safe to handle once unplugged?\u003c\/h3\u003e\u003cp\u003eDo not assume so. Stored energy requires proper qualified service.\u003c\/p\u003e\u003ch2\u003eNeed Help Confirming the Right Product?\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/garage-doorparts.com\/pages\/contact\"\u003eContact Garage-DoorParts.com before ordering\u003c\/a\u003e. Send the full equipment model, readable part labels and photographs of the installed assembly. Include the dimensions, electrical configuration or accessory details relevant to your project so the listing can be checked against the actual installation.\u003c\/p\u003e","brand":"Controlled Products","offers":[{"title":"Default Title","offer_id":60723447857438,"sku":"K29-10338","price":42.83,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0978\/2781\/5710\/files\/k29-10338.png?v=1793244926","url":"https:\/\/garage-doorparts.com\/products\/liftmaster-k29-10338","provider":"garage-doorparts.com","version":"1.0","type":"link"}