{"product_id":"liftmaster-k25-2015","title":"LiftMaster K25-2015 Overload Service Component — 15A","description":"\u003cp\u003e\u003cstrong\u003eThe LiftMaster K25-2015 is the 15A overload service reference identified in manufacturer parts literature. It is a protective electrical component selected by the exact operator, motor circuit and installed overload arrangement rather than by matching a relay case or current number alone. It must not be confused with an ordinary fuse or the 30A switching relays used elsewhere in operator controls. A tripping overload may be responding to a genuine motor, supply or mechanical problem, so the cause must be diagnosed before replacing the protective component.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eCompatibility — Models, Versions and Exclusions\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel or selection point\u003c\/th\u003e\n\u003cth\u003eCompatibility requirement\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperator circuits specifying K25-2015\u003c\/td\u003e\n\u003ctd\u003eMatch exact installed overload and motor requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15A designation\u003c\/td\u003e\n\u003ctd\u003eNot approval for every 15A circuit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOther overload ratings\u003c\/td\u003e\n\u003ctd\u003eDo not increase the rating to suppress trips.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e30A relay components\u003c\/td\u003e\n\u003ctd\u003eDifferent function and selection requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecurring overload trips\u003c\/td\u003e\n\u003ctd\u003eRequire supply, motor and mechanical diagnosis.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eFind the Cause of Tripping Before Replacing Protection\u003c\/h2\u003e\u003cp\u003eRecord the operator, motor and overload markings and preserve any useful fault history before service. Have qualified personnel inspect the supply, connections, motor condition and driven load. A door that binds, a brake that does not release or a damaged motor can cause repeated trips even when the overload itself is functioning correctly. Replacing protection without correcting the cause can leave the equipment unsafe or unreliable.\u003c\/p\u003e\u003cp\u003eMatch the replacement to the exact circuit diagram and current supplied instructions. Do not bridge the overload, increase its rating or assume a different component with a similar terminal layout provides the same protection. After repair, verify the intended protective and operating functions under the manufacturer procedure. Restore the enclosure and complete the required travel and safety checks before returning the equipment to normal use.\u003c\/p\u003e\u003ch2\u003eSpecifications and Product Identification\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart number\u003c\/td\u003e\n\u003ctd\u003eK25-2015\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct\u003c\/td\u003e\n\u003ctd\u003eOverload service component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent designation\u003c\/td\u003e\n\u003ctd\u003e15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelection basis\u003c\/td\u003e\n\u003ctd\u003eExact motor circuit and operator diagram\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeparate products\u003c\/td\u003e\n\u003ctd\u003eFuses and switching relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReset \/ adjustment details\u003c\/td\u003e\n\u003ctd\u003eConfirm delivered component instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eBefore Ordering\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eRecord full operator, motor and overload labels.\u003c\/li\u003e\n\u003cli\u003eConfirm K25-2015 and 15A requirement.\u003c\/li\u003e\n\u003cli\u003eDiagnose trips and inspect wiring and mechanical load.\u003c\/li\u003e\n\u003cli\u003eVerify exact mounting, connections and protective-function tests.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003ePackage Contents and Separate Requirements\u003c\/h2\u003e\u003cp\u003eThis offer identifies the K25-2015 overload service component. A motor starter, contactor set, fuse package, logic board, complete wiring harness and electrical enclosure are not promised as included. Confirm the current supplied component and any mounting pieces. The rating does not make it a complete replacement for every protective device in the control box; identify each damaged part separately through the correct operator circuit and repair information.\u003c\/p\u003e\u003ch2 class=\"safety-warning\"\u003eSafety Warnings — Read Before Installation or Service\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWARNING: Overload service involves hazardous electrical circuits and motor protection. Use qualified electrical and operator-service personnel.\u003c\/li\u003e\n\u003cli\u003eIsolate all applicable supplies before touching terminals or removing the component. Secure the driven equipment against movement.\u003c\/li\u003e\n\u003cli\u003eNever bypass an overload or increase its rating to stop nuisance trips. Diagnose and correct the underlying fault.\u003c\/li\u003e\n\u003cli\u003eRestore covers and verify protective function, normal operation and all required safety responses before use.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eRelated Products and Important Differences\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-photocell-kit-indoor-only-for-30-wide-openings\"\u003eCPS-U monitored photo eyes\u003c\/a\u003e — separate protection devices for approved commercial-door controls; match the operator and environment.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-extended-duty-trolley-operator\"\u003eTDC12X1BMC MAXUM trolley operator\u003c\/a\u003e — a complete-operator comparison, not evidence that this legacy service part fits MAXUM.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eIs it an ordinary fuse?\u003c\/h3\u003e\u003cp\u003eNo. The manufacturer identifies an overload service component.\u003c\/p\u003e\u003ch3\u003eCan I use a higher rating to stop trips?\u003c\/h3\u003e\u003cp\u003eNo. Preserve the specified motor-protection requirements.\u003c\/p\u003e\u003ch3\u003eDoes a trip prove the overload is bad?\u003c\/h3\u003e\u003cp\u003eNo. The device may be responding to a genuine fault.\u003c\/p\u003e\u003ch3\u003eIs a complete motor starter included?\u003c\/h3\u003e\u003cp\u003eNo. This offer identifies the individual service component.\u003c\/p\u003e\u003ch2\u003eNeed Help Confirming the Right Product?\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/garage-doorparts.com\/pages\/contact\"\u003eContact Garage-DoorParts.com before ordering\u003c\/a\u003e. Send the full equipment model, readable part labels and photographs of the installed assembly. Include the dimensions, electrical configuration or accessory details relevant to your project so the listing can be checked against the actual installation.\u003c\/p\u003e","brand":"Controlled Products","offers":[{"title":"Default Title","offer_id":60723627622686,"sku":"K25-2015","price":15.47,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0978\/2781\/5710\/files\/k25-2015.jpg?v=1793245136","url":"https:\/\/garage-doorparts.com\/products\/liftmaster-k25-2015","provider":"garage-doorparts.com","version":"1.0","type":"link"}