{"product_id":"liftmaster-k20-3075c-4p","title":"LiftMaster K20-3075C-4P Commercial Motor — Three-Quarter HP, 230\/ 460V Three-Phase C-Face","description":"\u003cp\u003e\u003cstrong\u003eThe LiftMaster K20-3075C-4P is the commercial motor service reference identified with 3\/4HP,230\/ 460V, three-phase and C-face mounting in manufacturer parts literature. Match the complete number and installed operator circuit before ordering. The similarly numbered-H25, foot-mount and other enclosure variants are separate service selections. This motor is not a complete drive kit or a means of changing an operator’s approved electrical supply or door capacity. Select the replacement by the complete part number and the installed equipment configuration. A similar photograph or a shared LiftMaster brand name does not establish interchangeability. Confirm the applicable service drawing before ordering so the repair addresses the correct component and its related mounting, connection and operating requirements.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eCompatibility — Models, Versions and Exclusions\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel or selection point\u003c\/th\u003e\n\u003cth\u003eCompatibility requirement\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrawings specifying K20-3075C-4P\u003c\/td\u003e\n\u003ctd\u003eVerify the actual operator generation and motor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-phase equipment\u003c\/td\u003e\n\u003ctd\u003eNot a direct phase conversion.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFoot-mount variants\u003c\/td\u003e\n\u003ctd\u003eDifferent mounting and potentially different drive interface.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-H25 or other suffixes\u003c\/td\u003e\n\u003ctd\u003eConfirm exact service selection; do not omit the suffix.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eIdentify the Assembly and Plan the Repair\u003c\/h2\u003e\u003cp\u003eRecord the existing motor label, mounting and drive connection and compare them with the correct repair drawing. A matching horsepower number alone does not establish speed, shaft, rotation, enclosure or wiring compatibility. No unverified RPM, frame size or capacitor requirement is assigned here.\u003c\/p\u003e\u003cp\u003eDiagnose the supply, controls and mechanical load before fitting a replacement motor. A brake fault, damaged reducer or binding door can overload a working motor. Follow the current connection diagram and approved mounting procedure, then verify rotation and complete operator function under controlled testing by qualified personnel.\u003c\/p\u003e\u003cp\u003eAn electrical symptom does not identify the failed component by itself. Have qualified service personnel inspect the supply, wiring, connections and equipment condition before replacing parts. Record existing labels and terminal references with power safely isolated. A replacement should restore the documented circuit arrangement; it should not be used to change operating voltage, defeat a protective function or compensate for a mechanical load that the equipment cannot safely move.\u003c\/p\u003e\u003cp\u003eCompare the delivered item with the approved service reference before installation. The installer must obtain the equipment-specific wiring, mounting and commissioning instructions rather than infer them from the appearance of the part. Keep conductors clear of moving components and reinstall the intended covers. After the repair, check the original complaint and the equipment’s required operating and safety functions; a successful power-up alone is not a complete service test.\u003c\/p\u003e\u003ch2\u003eSpecifications and Product Identification\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrdering reference\u003c\/td\u003e\n\u003ctd\u003eK20-3075C-4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e3\/4HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply designation\u003c\/td\u003e\n\u003ctd\u003e230\/ 460V, three phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eC-face\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelection basis\u003c\/td\u003e\n\u003ctd\u003eFull service number and exact motor\/operator nameplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eBefore Ordering\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConfirm the full unsuffixed motor reference.\u003c\/li\u003e\n\u003cli\u003eVerify3\/4HP,230\/ 460V and three-phase circuit.\u003c\/li\u003e\n\u003cli\u003eMatch C-face mounting and shaft engagement.\u003c\/li\u003e\n\u003cli\u003eInspect controls, drive alignment and door load.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003ePackage Contents and Separate Requirements\u003c\/h2\u003e\u003cp\u003eThe offer identifies the motor. Reducer, pulley, brake, complete starter, harness, mounting structure and operator are separate unless explicitly bundled. Confirm current connection and mounting pieces in the carton. A diagram grouping these drive components does not make them a combined motor order.\u003c\/p\u003e\u003ch2 class=\"safety-warning\"\u003eSafety Warnings — Read Before Installation or Service\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWARNING: Electrical service can expose hazardous voltage and moving equipment. Use qualified service personnel and electrical personnel where required.\u003c\/li\u003e\n\u003cli\u003eDisconnect every applicable mains, battery and auxiliary supply before work. Follow the equipment instructions for stored energy and safe isolation.\u003c\/li\u003e\n\u003cli\u003eThree-phase motor service requires qualified electrical personnel. Do not guess lead connections, change phase or alter protective settings to overcome mechanical resistance.\u003c\/li\u003e\n\u003cli\u003eRestore covers and wiring protection, then complete the model-specific functional and safety checks before returning the installation to normal use.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eRelated Products and Important Differences\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-photocell-kit-indoor-only-for-30-wide-openings\"\u003eCPS-U monitored photo eyes\u003c\/a\u003e — separate protection devices for approved commercial-door controls; match the operator and environment.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-extended-duty-trolley-operator\"\u003eTDC12X1BMC MAXUM trolley operator\u003c\/a\u003e — a complete-operator comparison, not evidence that this legacy service part fits MAXUM.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eCan it replace a single-phase motor directly?\u003c\/h3\u003e\u003cp\u003eNo. Phase and the complete approved circuit must match.\u003c\/p\u003e\u003ch3\u003eIs a reducer included?\u003c\/h3\u003e\u003cp\u003eNo reducer is promised.\u003c\/p\u003e\u003ch3\u003eMay I ignore-H25 on another motor?\u003c\/h3\u003e\u003cp\u003eNo. Match the complete service reference.\u003c\/p\u003e\u003ch3\u003eDoes it increase door capacity?\u003c\/h3\u003e\u003cp\u003eNo capacity upgrade is established by replacing this motor.\u003c\/p\u003e\u003ch2\u003eNeed Help Confirming the Right Product?\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/garage-doorparts.com\/pages\/contact\"\u003eContact Garage-DoorParts.com before ordering\u003c\/a\u003e. Send the full equipment model, readable part labels and photographs of the installed assembly. Include the dimensions, electrical configuration or accessory details relevant to your project so the listing can be checked against the actual installation.\u003c\/p\u003e","brand":"Controlled Products","offers":[{"title":"Default Title","offer_id":60723723960606,"sku":"K20-3075C-4P","price":1856.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0978\/2781\/5710\/files\/k20-3075c-4p.jpg?v=1793245248","url":"https:\/\/garage-doorparts.com\/products\/liftmaster-k20-3075c-4p","provider":"garage-doorparts.com","version":"1.0","type":"link"}