{"product_id":"liftmaster-k030b0652-1","title":"LiftMaster K030B0652-1 Motor Capacitor — 89µF, 120V","description":"\u003cp\u003e\u003cstrong\u003eThe LiftMaster K030B0652-1 is the manufacturer-listed 89µF, 120V motor-capacitor replacement for selected residential garage-door openers. The current manufacturer compatibility information includes 8587, 8587W, 8587WL and 85870 arrangements. Match the exact opener, capacitor and mounting before ordering. This is a motor-circuit component, separate from the motor and logic board; the voltage designation does not mean every 120V opener uses this capacitance. Select the replacement by the complete part number and the installed equipment configuration. A similar photograph or a shared LiftMaster brand name does not establish interchangeability. Confirm the applicable service drawing before ordering so the repair addresses the correct component and its related mounting, connection and operating requirements.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eCompatibility — Models, Versions and Exclusions\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel or selection point\u003c\/th\u003e\n\u003cth\u003eCompatibility requirement\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer-listed 8587-family arrangements\u003c\/td\u003e\n\u003ctd\u003eConfirm the complete model and service reference.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOther120V openers\u003c\/td\u003e\n\u003ctd\u003eVoltage alone does not establish capacitor compatibility.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDifferent capacitance ratings\u003c\/td\u003e\n\u003ctd\u003eDo not substitute to alter motor behavior.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor and main board\u003c\/td\u003e\n\u003ctd\u003eSeparate components; capacitor replacement is not complete drive renewal.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eIdentify the Assembly and Plan the Repair\u003c\/h2\u003e\u003cp\u003eA humming motor or failed start does not prove the capacitor is the only failed part. Have qualified service personnel check the circuit and mechanical load. A binding door, damaged motor or connection fault may need separate correction before the replacement is fitted.\u003c\/p\u003e\u003cp\u003eCapacitors can retain stored energy after power is disconnected. Use qualified service and the exact safe handling procedure rather than an improvised discharge method. Match the specified capacitance, voltage designation, terminals and mounting and do not borrow a value from a similar opener. Restore covers and complete the opener’s required operating and reversal tests after repair.\u003c\/p\u003e\u003cp\u003eAn electrical symptom does not identify the failed component by itself. Have qualified service personnel inspect the supply, wiring, connections and equipment condition before replacing parts. Record existing labels and terminal references with power safely isolated. A replacement should restore the documented circuit arrangement; it should not be used to change operating voltage, defeat a protective function or compensate for a mechanical load that the equipment cannot safely move.\u003c\/p\u003e\u003cp\u003eCompare the delivered item with the approved service reference before installation. The installer must obtain the equipment-specific wiring, mounting and commissioning instructions rather than infer them from the appearance of the part. Keep conductors clear of moving components and reinstall the intended covers. After the repair, check the original complaint and the equipment’s required operating and safety functions; a successful power-up alone is not a complete service test.\u003c\/p\u003e\u003ch2\u003eSpecifications and Product Identification\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrdering reference\u003c\/td\u003e\n\u003ctd\u003eK030B0652-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e89µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer voltage designation\u003c\/td\u003e\n\u003ctd\u003e120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListed examples\u003c\/td\u003e\n\u003ctd\u003e8587, 8587W, 8587WL, 85870\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAliases\u003c\/td\u003e\n\u003ctd\u003e30B652, 30B0652, 030B0652-1, 030B0652\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eBefore Ordering\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConfirm K030B0652-1 or a documented alias.\u003c\/li\u003e\n\u003cli\u003eMatch 89µF and the 120V designation.\u003c\/li\u003e\n\u003cli\u003eVerify the exact opener and mounting arrangement.\u003c\/li\u003e\n\u003cli\u003eDiagnose motor, wiring and door resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003ePackage Contents and Separate Requirements\u003c\/h2\u003e\u003cp\u003eThis offer identifies the motor capacitor. Motor, mounting bracket, wiring harness, gear set, logic board and complete opener are separate unless expressly included. Confirm current connection and mounting pieces with the supplier. A capacitor-only order does not provide a full motor kit or establish that every motor fault can be resolved by this component.\u003c\/p\u003e\u003ch2 class=\"safety-warning\"\u003eSafety Warnings — Read Before Installation or Service\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWARNING: Electrical service can expose hazardous voltage and moving equipment. Use qualified service personnel and electrical personnel where required.\u003c\/li\u003e\n\u003cli\u003eDisconnect every applicable mains, battery and auxiliary supply before work. Follow the equipment instructions for stored energy and safe isolation.\u003c\/li\u003e\n\u003cli\u003eCapacitors can retain hazardous stored energy after isolation. Use qualified service personnel and the exact safe handling procedure; do not improvise a discharge method or substitute capacitance.\u003c\/li\u003e\n\u003cli\u003eRestore covers and wiring protection, then complete the model-specific functional and safety checks before returning the installation to normal use.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eRelated Products and Important Differences\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-photocell-kit-indoor-only-for-30-wide-openings\"\u003eCPS-U monitored photo eyes\u003c\/a\u003e — separate protection devices for approved commercial-door controls; match the operator and environment.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-extended-duty-trolley-operator\"\u003eTDC12X1BMC MAXUM trolley operator\u003c\/a\u003e — a complete-operator comparison, not evidence that this legacy service part fits MAXUM.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat capacitance is listed?\u003c\/h3\u003e\u003cp\u003eThe manufacturer specifies 89µF.\u003c\/p\u003e\u003ch3\u003eDoes 120V mean it fits every 120V opener?\u003c\/h3\u003e\u003cp\u003eNo. Capacitance, circuit and physical mounting must match.\u003c\/p\u003e\u003ch3\u003eIs a motor included?\u003c\/h3\u003e\u003cp\u003eNo motor is promised.\u003c\/p\u003e\u003ch3\u003eCan it still store energy after isolation?\u003c\/h3\u003e\u003cp\u003eYes. Qualified personnel must follow the correct capacitor-handling procedure.\u003c\/p\u003e\u003ch2\u003eNeed Help Confirming the Right Product?\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/garage-doorparts.com\/pages\/contact\"\u003eContact Garage-DoorParts.com before ordering\u003c\/a\u003e. Send the full equipment model, readable part labels and photographs of the installed assembly. Include the dimensions, electrical configuration or accessory details relevant to your project so the listing can be checked against the actual installation.\u003c\/p\u003e","brand":"Controlled Products","offers":[{"title":"Default Title","offer_id":60723700072734,"sku":"K030B0652-1","price":66.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0978\/2781\/5710\/files\/k030b0652-1.png?v=1793245233","url":"https:\/\/garage-doorparts.com\/products\/liftmaster-k030b0652-1","provider":"garage-doorparts.com","version":"1.0","type":"link"}