{"product_id":"liftmaster-k03-8224-d","title":"LiftMaster K03-8224-D D-Line Contactor — 24V Designation","description":"\u003cp\u003e\u003cstrong\u003eThe LiftMaster K03-8224-D identifies a D-line contactor with a 24V designation for the applicable commercial operator circuit. It is an exact service reference, not a universal substitute for any relay or contactor bearing a similar voltage marking. Match the installed contactor label, wiring diagram and operator configuration before selecting the replacement. Select the replacement by the complete part number and the installed equipment configuration. A similar photograph or a shared LiftMaster brand name does not establish interchangeability. Confirm the applicable service drawing before ordering so the repair addresses the correct component and its related mounting, connection and operating requirements.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eCompatibility — Models, Versions and Exclusions\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel or selection point\u003c\/th\u003e\n\u003cth\u003eCompatibility requirement\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecified operator circuit\u003c\/td\u003e\n\u003ctd\u003eUse where the applicable wiring and parts information call for K03-8224-D.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil type\u003c\/td\u003e\n\u003ctd\u003eDo not infer AC or DC coil compatibility from 24V alone.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact arrangement\u003c\/td\u003e\n\u003ctd\u003eVerify required poles, auxiliary contacts and terminal assignments.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOther K03 references\u003c\/td\u003e\n\u003ctd\u003eA similar number or voltage does not establish matching load ratings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eIdentify the Assembly and Plan the Repair\u003c\/h2\u003e\u003cp\u003eA contactor must match both its control side and the load it switches. A matching nominal voltage does not establish the correct coil type, contact rating, pole arrangement or mechanical fit. Have the technician compare the complete label and documented terminal function rather than move wires according to a photograph of another operator.\u003c\/p\u003e\u003cp\u003eChattering, burned contacts or failure to pull in can be symptoms of a supply, wiring or load problem. Diagnose those conditions before replacing the contactor so the new component is not exposed to the same fault. This listing does not identify a complete reversing starter or authorize modifying overload protection, interlocks or the operator’s documented control sequence.\u003c\/p\u003e\u003cp\u003eAn electrical symptom does not identify the failed component by itself. Have qualified service personnel inspect the supply, wiring, connections and equipment condition before replacing parts. Record existing labels and terminal references with power safely isolated. A replacement should restore the documented circuit arrangement; it should not be used to change operating voltage, defeat a protective function or compensate for a mechanical load that the equipment cannot safely move.\u003c\/p\u003e\u003ch2\u003eSpecifications and Product Identification\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrdering reference\u003c\/td\u003e\n\u003ctd\u003eK03-8224-D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent\u003c\/td\u003e\n\u003ctd\u003eD-line contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage designation\u003c\/td\u003e\n\u003ctd\u003e24V; verify the precise coil specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact ratings\u003c\/td\u003e\n\u003ctd\u003eConfirm from the approved replacement label and service data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrdering requirement\u003c\/td\u003e\n\u003ctd\u003eComplete K03-8224-D reference, including suffix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eBefore Ordering\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eRecord the complete contactor label and operator model.\u003c\/li\u003e\n\u003cli\u003eVerify coil specification and the documented 24V circuit.\u003c\/li\u003e\n\u003cli\u003eMatch load ratings, contacts, terminals and mounting.\u003c\/li\u003e\n\u003cli\u003eInspect for the cause of overheating, chatter or control-voltage loss.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003ePackage Contents and Separate Requirements\u003c\/h2\u003e\u003cp\u003eThis offer identifies the K03-8224-D contactor service component. Do not assume that an overload device, reversing-contactor pair, complete electrical enclosure, wire harness or mounting adaptation is included. Confirm the current contactor configuration and any separately required service hardware before ordering.\u003c\/p\u003e\u003ch2 class=\"safety-warning\"\u003eSafety Warnings — Read Before Installation or Service\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWARNING: Electrical service can expose hazardous voltage and moving equipment. Use qualified service personnel and electrical personnel where required.\u003c\/li\u003e\n\u003cli\u003eDisconnect every applicable mains, battery and auxiliary supply before work. Follow the equipment instructions for stored energy and safe isolation.\u003c\/li\u003e\n\u003cli\u003eDo not bypass grounding, overload protection, monitored safety devices or fire-control functions to make the equipment operate. Diagnose the underlying fault.\u003c\/li\u003e\n\u003cli\u003eRestore covers and wiring protection, then complete the model-specific functional and safety checks before returning the installation to normal use.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eRelated Products and Important Differences\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-photocell-kit-indoor-only-for-30-wide-openings\"\u003eCPS-U monitored photo eyes\u003c\/a\u003e — separate protection devices for approved commercial-door controls; match the operator and environment.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-extended-duty-trolley-operator\"\u003eTDC12X1BMC MAXUM trolley operator\u003c\/a\u003e — a complete-operator comparison, not evidence that this legacy service part fits MAXUM.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eDoes 24V alone establish compatibility?\u003c\/h3\u003e\u003cp\u003eNo. Coil type, load ratings, contact arrangement, terminals and the exact service reference must all match.\u003c\/p\u003e\u003ch3\u003eIs the coil definitely DC?\u003c\/h3\u003e\u003cp\u003eThat is not established by this listing. Verify the actual approved coil marking and equipment wiring information.\u003c\/p\u003e\u003ch3\u003eDoes it include a complete starter assembly?\u003c\/h3\u003e\u003cp\u003eNo complete starter or reversing assembly is identified. Confirm the current single-component package.\u003c\/p\u003e\u003ch3\u003eWill replacement correct an overloaded motor?\u003c\/h3\u003e\u003cp\u003eIt will not correct the underlying load fault. Have the motor, supply and driven equipment checked as part of diagnosis.\u003c\/p\u003e\u003ch2\u003eNeed Help Confirming the Right Product?\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/garage-doorparts.com\/pages\/contact\"\u003eContact Garage-DoorParts.com before ordering\u003c\/a\u003e. Send the full equipment model, readable part labels and photographs of the installed assembly. Include the dimensions, electrical configuration or accessory details relevant to your project so the listing can be checked against the actual installation.\u003c\/p\u003e","brand":"Controlled Products","offers":[{"title":"Default Title","offer_id":60723988627742,"sku":"K03-8224-D","price":342.24,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0978\/2781\/5710\/files\/k03-8224-d.png?v=1793245323","url":"https:\/\/garage-doorparts.com\/products\/liftmaster-k03-8224-d","provider":"garage-doorparts.com","version":"1.0","type":"link"}