{"product_id":"liftmaster-g02102","title":"LiftMaster G02102 Two-Button Indoor Surface-Mount Control Station — Constant-Pressure Application","description":"\u003cp\u003e\u003cstrong\u003eThe LiftMaster G02102 is the supplier ordering reference for the two-button, indoor surface-mount control station. The documented application uses OPEN and CLOSE commands with an operator wired for constant pressure in both directions, corresponding to the stated D1 control arrangement. It is not a complete three-button station and should not be selected as a universal momentary-command replacement without checking the operator wiring. Select the replacement by the complete part number and the installed equipment configuration. A similar photograph or a shared LiftMaster brand name does not establish interchangeability. Confirm the applicable service drawing before ordering so the repair addresses the correct component and its related mounting, connection and operating requirements.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eCompatibility — Models, Versions and Exclusions\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel or selection point\u003c\/th\u003e\n\u003cth\u003eCompatibility requirement\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eD1 constant-pressure control\u003c\/td\u003e\n\u003ctd\u003eVerify the operator’s approved wiring and station requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMomentary-command circuits\u003c\/td\u003e\n\u003ctd\u003eNo automatic substitution established.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor or wet locations\u003c\/td\u003e\n\u003ctd\u003eThe cited offer is for interior use.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThree-button STOP stations\u003c\/td\u003e\n\u003ctd\u003eDifferent command set and control arrangement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eIdentify the Assembly and Plan the Repair\u003c\/h2\u003e\u003cp\u003eIdentify the intended operator control mode before ordering the station. Two visible buttons do not establish whether a system uses constant-pressure or momentary commands, nor do they determine all required stop and interlock functions. Have the installer confirm the circuit and station placement using the exact operator instructions.\u003c\/p\u003e\u003cp\u003eLocate controls where the user can observe the door and remain clear of its moving parts, following the manufacturer installation requirements. The station does not replace protection devices or authorize defeating monitored inputs. If the existing installation requires a separate stop function or other controls, preserve that arrangement rather than assuming two buttons cover every requirement.\u003c\/p\u003e\u003cp\u003eAn electrical symptom does not identify the failed component by itself. Have qualified service personnel inspect the supply, wiring, connections and equipment condition before replacing parts. Record existing labels and terminal references with power safely isolated. A replacement should restore the documented circuit arrangement; it should not be used to change operating voltage, defeat a protective function or compensate for a mechanical load that the equipment cannot safely move.\u003c\/p\u003e\u003cp\u003eCompare the delivered item with the approved service reference before installation. The installer must obtain the equipment-specific wiring, mounting and commissioning instructions rather than infer them from the appearance of the part. Keep conductors clear of moving components and reinstall the intended covers. After the repair, check the original complaint and the equipment’s required operating and safety functions; a successful power-up alone is not a complete service test.\u003c\/p\u003e\u003ch2\u003eSpecifications and Product Identification\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrdering reference\u003c\/td\u003e\n\u003ctd\u003eG02102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eButtons\u003c\/td\u003e\n\u003ctd\u003eTwo: OPEN and CLOSE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eSurface mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocation\u003c\/td\u003e\n\u003ctd\u003eInterior use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl requirement\u003c\/td\u003e\n\u003ctd\u003eApproved constant-pressure open\/close arrangement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eBefore Ordering\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConfirm the full G02102 station offer.\u003c\/li\u003e\n\u003cli\u003eVerify indoor surface mounting.\u003c\/li\u003e\n\u003cli\u003eMatch the constant-pressure control arrangement.\u003c\/li\u003e\n\u003cli\u003eReview visibility, wiring and all required stop\/interlock functions.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003ePackage Contents and Separate Requirements\u003c\/h2\u003e\u003cp\u003eThe listing identifies the two-button station. Operator, external safety sensors, field wiring, conduit and any separate stop station are separate unless expressly bundled. Confirm the current enclosure and mounting hardware with the supplier. A station-only order does not provide a complete operator control conversion or establish compatibility with every commercial control circuit.\u003c\/p\u003e\u003ch2 class=\"safety-warning\"\u003eSafety Warnings — Read Before Installation or Service\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWARNING: Electrical service can expose hazardous voltage and moving equipment. Use qualified service personnel and electrical personnel where required.\u003c\/li\u003e\n\u003cli\u003eDisconnect every applicable mains, battery and auxiliary supply before work. Follow the equipment instructions for stored energy and safe isolation.\u003c\/li\u003e\n\u003cli\u003eThis two-button station does not provide a separate STOP button. Do not use it to remove required stopping or interlock functions; match the approved constant-pressure wiring.\u003c\/li\u003e\n\u003cli\u003eRestore covers and wiring protection, then complete the model-specific functional and safety checks before returning the installation to normal use.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eRelated Products and Important Differences\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-photocell-kit-indoor-only-for-30-wide-openings\"\u003eCPS-U monitored photo eyes\u003c\/a\u003e — separate protection devices for approved commercial-door controls; match the operator and environment.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-extended-duty-trolley-operator\"\u003eTDC12X1BMC MAXUM trolley operator\u003c\/a\u003e — a complete-operator comparison, not evidence that this legacy service part fits MAXUM.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eIs it for outdoor use?\u003c\/h3\u003e\u003cp\u003eThe documented offer is for interior use only.\u003c\/p\u003e\u003ch3\u003eDoes it provide a separate STOP button?\u003c\/h3\u003e\u003cp\u003eIt is a two-button OPEN\/CLOSE station; review the complete required control arrangement.\u003c\/p\u003e\u003ch3\u003eCan I assume momentary operation?\u003c\/h3\u003e\u003cp\u003eNo. The stated application requires constant pressure in both directions.\u003c\/p\u003e\u003ch3\u003eDoes it replace safety sensors?\u003c\/h3\u003e\u003cp\u003eNo. Required protection remains part of the operator system.\u003c\/p\u003e\u003ch2\u003eNeed Help Confirming the Right Product?\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/garage-doorparts.com\/pages\/contact\"\u003eContact Garage-DoorParts.com before ordering\u003c\/a\u003e. Send the full equipment model, readable part labels and photographs of the installed assembly. Include the dimensions, electrical configuration or accessory details relevant to your project so the listing can be checked against the actual installation.\u003c\/p\u003e","brand":"Controlled Products","offers":[{"title":"Default Title","offer_id":60723684081950,"sku":"G02102","price":42.26,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0978\/2781\/5710\/files\/g02102.png?v=1793245209","url":"https:\/\/garage-doorparts.com\/products\/liftmaster-g02102","provider":"garage-doorparts.com","version":"1.0","type":"link"}