{"product_id":"liftmaster-cpicard","title":"LiftMaster CPICARD Commercial Safety-Device Interface Card","description":"\u003cp\u003e\u003cstrong\u003eThe LiftMaster CPICARD is an interface for documented safety-device connections to compatible non-monitored commercial door operators. It is used in specified photo-eye and light-curtain arrangements where the device signal must be adapted to the operator’s input. Adding this card does not make the entire operator a fully monitored entrapment-protection system: the operator-side connection remains the limiting distinction. Select CPICARD only after a qualified commercial-door technician has reviewed the exact operator, intended devices and required operating mode. The supplier’s phrase “Phase Kit” does not mean this card converts motor voltage or electrical phase.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eCompatibility — Models, Versions and Exclusions\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel or selection point\u003c\/th\u003e\n\u003cth\u003eCompatibility requirement\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported non-monitored commercial operators\u003c\/td\u003e\n\u003ctd\u003eVerify the exact input, available supply and manufacturer interface procedure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLC-36A with \u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-photocell-kit-indooroutdoor-for-45-openings-nema-4-rated\"\u003eCPS-OPEN4\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003eManufacturer addendum specifies this combined arrangement; the photo eyes remain required.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOther photo-eye or edge configurations\u003c\/td\u003e\n\u003ctd\u003eUse the instructions for the exact device and interface; do not assume universal sensor support.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-36-tall-light-curtain-monitoredprimary\"\u003eLC36M\u003c\/a\u003e monitored light curtain\u003c\/td\u003e\n\u003ctd\u003eDifferent product from LC-36A; do not transfer the older interface procedure automatically.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor phase or voltage conversion\u003c\/td\u003e\n\u003ctd\u003eNot the function of CPICARD; select electrical conversion equipment separately where approved.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eUnderstand Where Monitoring Stops Before Choosing a Retrofit\u003c\/h2\u003e\u003cp\u003eThe interface can accept the specified device signals and present the documented output to an older operator. That connection is different from an operator that directly supervises its approved protection system. A working beam test alone does not prove complete monitored operation, and the card should not be used to claim that an older operator now has all the capabilities of a newer monitored model.\u003c\/p\u003e\u003cp\u003eFor the manufacturer’s LC-36A arrangement, \u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-photocell-kit-indooroutdoor-for-45-openings-nema-4-rated\"\u003eCPS-OPEN4\u003c\/a\u003e photo eyes are required alongside the curtain. The addendum does not authorize arbitrary photo-eye substitutions or guarantee operation with every brand of operator. Have the installer evaluate the intended closing mode and complete protection requirements before deciding whether this interface is appropriate or whether another equipment solution is needed.\u003c\/p\u003e\u003ch2\u003eSpecifications and Product Identification\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCPICARD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct\u003c\/td\u003e\n\u003ctd\u003eCommercial safety-device interface card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDocumented role\u003c\/td\u003e\n\u003ctd\u003eInterface to a compatible non-monitored operator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary illustrated application\u003c\/td\u003e\n\u003ctd\u003eLC-36A with \u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-photocell-kit-indooroutdoor-for-45-openings-nema-4-rated\"\u003eCPS-OPEN4\u003c\/a\u003e photo eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperator-side interface\u003c\/td\u003e\n\u003ctd\u003eSpecified non-monitored edge\/common input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImportant limitation\u003c\/td\u003e\n\u003ctd\u003eDoes not create complete operator-level monitored protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eBefore Ordering\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIdentify the exact operator, control generation and intended operating mode.\u003c\/li\u003e\n\u003cli\u003eConfirm the approved device combination and operator-side input requirements.\u003c\/li\u003e\n\u003cli\u003eReview the complete manufacturer instructions for the interface and each connected sensor.\u003c\/li\u003e\n\u003cli\u003eEstablish the required supply, installation parts and commissioning tests before ordering.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003ePackage Contents and Separate Requirements\u003c\/h2\u003e\u003cp\u003eThis offer identifies the interface card. Photo eyes, a light curtain, sensing edge, external power supply, field wiring and operator are not promised as included. The documented LC-36A arrangement may require a separately selected 100MAPS supply when suitable operator power is unavailable. Confirm the complete equipment list rather than assuming a card-only purchase supplies the protection devices or all power needed for the installation.\u003c\/p\u003e\u003ch2 class=\"safety-warning\"\u003eSafety Warnings — Read Before Installation or Service\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWARNING: An incorrectly selected or connected interface can leave a closing door without the intended protection. Installation and testing require a qualified commercial-door technician.\u003c\/li\u003e\n\u003cli\u003eDisconnect operator and accessory power before wiring. Use the exact manufacturer connection procedure and approved device combination.\u003c\/li\u003e\n\u003cli\u003eNever use CPICARD to bypass a failed safety input or represent a non-monitored operator as fully monitored. Preserve all required protection and operating restrictions.\u003c\/li\u003e\n\u003cli\u003eTest every installed protection device and the prescribed door response before normal use. Keep people clear during testing and correct any unreliable or unexpected response.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eRelated Products and Important Differences\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-photocell-kit-indooroutdoor-for-45-openings-nema-4-rated\"\u003eCPS-OPEN4 monitored photo-eye kit\u003c\/a\u003e — the photo-eye model specified in the documented LC-36A interface arrangement; follow the complete addendum.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-36-tall-light-curtain-monitoredprimary\"\u003eLC36M monitored light curtain\u003c\/a\u003e — a different curtain for approved monitored systems; not an automatic substitute for LC-36A in this retrofit.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eDoes CPICARD make an older operator fully monitored?\u003c\/h3\u003e\u003cp\u003eNo. Do not confuse device-to-interface signaling with complete monitoring by the operator.\u003c\/p\u003e\u003ch3\u003eCan LC-36A be used alone in the documented retrofit?\u003c\/h3\u003e\u003cp\u003eNo. The manufacturer addendum specifies \u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-photocell-kit-indooroutdoor-for-45-openings-nema-4-rated\"\u003eCPS-OPEN4\u003c\/a\u003e photo eyes as part of that arrangement.\u003c\/p\u003e\u003ch3\u003eIs \u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-36-tall-light-curtain-monitoredprimary\"\u003eLC36M\u003c\/a\u003e the same curtain as LC-36A?\u003c\/h3\u003e\u003cp\u003eNo. They are different products with their own compatibility and installation requirements.\u003c\/p\u003e\u003ch3\u003eDoes “Phase Kit” mean it converts single-phase power to three-phase?\u003c\/h3\u003e\u003cp\u003eNo. CPICARD is a signal-interface product, not a motor phase-conversion device.\u003c\/p\u003e\u003ch2\u003eNeed Help Confirming the Right Product?\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/garage-doorparts.com\/pages\/contact\"\u003eContact Garage-DoorParts.com before ordering\u003c\/a\u003e. Send the full equipment model, readable part labels and photographs of the installed assembly. Include the dimensions, electrical configuration or accessory details relevant to your project so the listing can be checked against the actual installation.\u003c\/p\u003e","brand":"Controlled Products","offers":[{"title":"Default Title","offer_id":60655789539614,"sku":"CPICARD","price":89.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0978\/2781\/5710\/files\/cpicard.jpg?v=1793140000","url":"https:\/\/garage-doorparts.com\/products\/liftmaster-cpicard","provider":"garage-doorparts.com","version":"1.0","type":"link"}