{"product_id":"liftmaster-capxlv2","title":"LiftMaster CAPXLV2 Smart Video Intercom-L — 10-Inch Touchscreen, myQ Community","description":"\u003cp\u003e\u003cstrong\u003eThe LiftMaster CAPXLV2 Smart Video Intercom-L provides a 10-inch touchscreen and visitor video for larger residential communities and multi-entrance access systems. The supplier identifies the offered manufacturer reference as CAPXLV2MC. It combines Ethernet or Wi-Fi connectivity with reader inputs and relay outputs for a professionally designed installation. myQ Community service is required, and the manufacturer specifies Phone.com VoIP service for calling. Select the intercom with its power source, entrance hardware and subscriptions rather than treating the screen alone as a complete access system.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eCompatibility — Models, Versions and Exclusions\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel or selection point\u003c\/th\u003e\n\u003cth\u003eCompatibility requirement\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunity door and gate entrances\u003c\/td\u003e\n\u003ctd\u003eMatch reader interfaces, relay functions and controlled hardware to the installation design.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproved LiftMaster wireless gate link\u003c\/td\u003e\n\u003ctd\u003eVerify the exact operator and firmware; wireless control does not remove power and network requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE installations\u003c\/td\u003e\n\u003ctd\u003eUse the specified 802.3bt Type 3 power arrangement; an ordinary low-power PoE port is not automatically suitable.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEarlier CAPXL \/ CAPXLV models\u003c\/td\u003e\n\u003ctd\u003eDifferent generations; do not assume identical power, mounting or accessory requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eDesign the Entrances, Network and Service Plan Together\u003c\/h2\u003e\u003cp\u003eThe reader and relay counts describe available interfaces, not a guarantee that every combination of doors, locks and readers can be connected without additional hardware. Have the access-control installer map each entrance, its reader, release device and required control functions. Confirm the electrical ratings and any separate lock supplies from the installation manual.\u003c\/p\u003e\u003cp\u003eAccount setup is part of commissioning. Establish the property account, subscription, resident credentials and app licenses before relying on visitor calls. The manufacturer manual identifies Phone.com as the supported VoIP service for calling; do not assume any existing telephone provider can be reused. Video retention and app entitlements depend on the selected services, so confirm current plan terms before purchase.\u003c\/p\u003e\u003ch2\u003eSpecifications and Product Identification\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupplier model\u003c\/td\u003e\n\u003ctd\u003eCAPXLV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer reference\u003c\/td\u003e\n\u003ctd\u003eCAPXLV2MC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e10-inch HD touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCamera\u003c\/td\u003e\n\u003ctd\u003e1080p; 135-degree field of view\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork\u003c\/td\u003e\n\u003ctd\u003eEthernet or Wi-Fi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReader interfaces\u003c\/td\u003e\n\u003ctd\u003eFour Wiegand inputs and four OSDP reader interfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay outputs\u003c\/td\u003e\n\u003ctd\u003eEight; configure for the intended access-control functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService requirements\u003c\/td\u003e\n\u003ctd\u003emyQ Community subscription; Phone.com VoIP for calling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eBefore Ordering\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eList the entrances, existing readers, locks and gate operators to be controlled.\u003c\/li\u003e\n\u003cli\u003eConfirm Ethernet or Wi-Fi availability and the required network performance.\u003c\/li\u003e\n\u003cli\u003eSelect the approved 24V DC or specified PoE supply arrangement using the current manual.\u003c\/li\u003e\n\u003cli\u003eConfirm surface, flush or pedestal mounting requirements and establish the service accounts.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003ePackage Contents and Separate Requirements\u003c\/h2\u003e\u003cp\u003eThis SKU identifies the CAPXLV2 intercom offer. Confirm the supplied power equipment and mounting parts in the current carton. Additional readers, electric locks, gate operators, a PoE injector, pedestal, network service and subscriptions should not be assumed included. When replacing an earlier intercom, have the installer compare the existing wiring and cutout with this model’s drawings before scheduling the changeover.\u003c\/p\u003e\u003ch2 class=\"safety-warning\"\u003eSafety Warnings — Read Before Installation or Service\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWARNING: Incorrect access-control installation can cause unsafe release or movement of an opening. Use a qualified access-control professional.\u003c\/li\u003e\n\u003cli\u003eDisconnect power before wiring and follow the specified grounding and electrical protection instructions.\u003c\/li\u003e\n\u003cli\u003eDo not use an underspecified PoE supply or connect lock loads without verifying the required electrical interface.\u003c\/li\u003e\n\u003cli\u003eVisitor video does not replace gate entrapment protection or required egress. Test calling, authorized release and independent safety functions before normal use.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eRelated Products and Important Differences\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-wireless-security-20-keypad-metal\"\u003eKPW250 wireless keypad\u003c\/a\u003e — a separate access method for compatible operators; it does not provide this intercom’s display, video or cloud functions.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-lmrrul-monitored-retro-reflective-photo-eye\"\u003eLMRRUL monitored photo eye\u003c\/a\u003e — a separate gate-protection component for approved controls; the intercom camera is not a monitored safety sensor.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eDoes CAPXLV2 require a subscription?\u003c\/h3\u003e\u003cp\u003eYes. myQ Community services are required for full function, and the manual specifies Phone.com VoIP for calling.\u003c\/p\u003e\u003ch3\u003eCan it use any PoE network switch?\u003c\/h3\u003e\u003cp\u003eNo. The power source must meet the stated 802.3bt Type 3 requirements and the supplied revision’s instructions.\u003c\/p\u003e\u003ch3\u003eDo eight relay outputs mean eight complete door systems are included?\u003c\/h3\u003e\u003cp\u003eNo. They are control interfaces. Readers, locks, power supplies and installation materials must be selected for the actual design.\u003c\/p\u003e\u003ch3\u003eIs this the same model as CAPXLV?\u003c\/h3\u003e\u003cp\u003eNo. CAPXLV2 is a distinct generation. Check power, mounting and accessory compatibility before replacing an earlier unit.\u003c\/p\u003e\u003ch2\u003eNeed Help Confirming the Right Product?\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/garage-doorparts.com\/pages\/contact\"\u003eContact Garage-DoorParts.com before ordering\u003c\/a\u003e. Send the full equipment model, readable part labels and photographs of the installed assembly. Include the dimensions, electrical configuration or accessory details relevant to your project so the listing can be checked against the actual installation.\u003c\/p\u003e","brand":"LiftMaster","offers":[{"title":"Default Title","offer_id":60655770468638,"sku":"CAPXLV2","price":4546.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0978\/2781\/5710\/files\/capxlv2.png?v=1793139886","url":"https:\/\/garage-doorparts.com\/products\/liftmaster-capxlv2","provider":"garage-doorparts.com","version":"1.0","type":"link"}