{"product_id":"liftmaster-capac","title":"LiftMaster CAPAC Smart Access Hub — myQ Community Access Integration","description":"\u003cp\u003e\u003cstrong\u003eThe LiftMaster CAPAC Smart Access Hub adds supported cloud-managed access functions to an existing door or gate installation through its documented control and status interfaces. It is intended for a properly configured myQ Community installation, with account setup, a device subscription and a suitable network connection treated as separate project requirements. CAPAC is an access-control hub, not a video intercom or a gate motor. Before ordering, have the installer confirm the operator or lock interface, status sensing, power arrangement and service plan for each access point.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eCompatibility — Models, Versions and Exclusions\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel or selection point\u003c\/th\u003e\n\u003cth\u003eCompatibility requirement\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported door and gate control circuits\u003c\/td\u003e\n\u003ctd\u003eMatch the documented relay interface and required power and status connections.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Wiegand access controllers\u003c\/td\u003e\n\u003ctd\u003eConfirm supported output format and host configuration; Wiegand outputs are not reader inputs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExisting locks\u003c\/td\u003e\n\u003ctd\u003eRequire their own suitable power and safe egress arrangement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsumer myQ garage hubs\u003c\/td\u003e\n\u003ctd\u003eDifferent product role; do not assume identical setup or subscription requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVideo-intercom functions\u003c\/td\u003e\n\u003ctd\u003eNo camera, touchscreen or audio intercom is supplied by a hub-only installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003ePlan the Access Point, Network and Account Together\u003c\/h2\u003e\u003cp\u003eThe hub can issue a command only through the installed interface, and meaningful door or gate status requires the appropriate sensing connection. Review the complete access point rather than treating the hub as a wireless replacement for every existing controller. Decide who will manage credentials, schedules and account access before the equipment is commissioned.\u003c\/p\u003e\u003cp\u003eVerify reliable connectivity at the final mounting location and use the network requirements for the supplied hardware and current service. The manufacturer recommends at least 1Mbps upload and download capacity per hub, allowing for other network traffic. Hidden Wi-Fi names and networks requiring a secondary sign-in are not supported in the documented arrangement. Confirm cellular availability and plan requirements separately rather than assuming an active cellular service is included.\u003c\/p\u003e\u003ch2\u003eSpecifications and Product Identification\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCAPAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct\u003c\/td\u003e\n\u003ctd\u003eSmart Access Hub\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement platform\u003c\/td\u003e\n\u003ctd\u003emyQ Community\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDocumented control interfaces\u003c\/td\u003e\n\u003ctd\u003eTwo relay outputs and two Wiegand outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork options\u003c\/td\u003e\n\u003ctd\u003eEthernet \/ Wi-Fi; cellular requirements depend on the current configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWi-Fi band\u003c\/td\u003e\n\u003ctd\u003e2.4GHz in the documented b\/g\/n arrangement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccount requirement\u003c\/td\u003e\n\u003ctd\u003eFacility setup and device subscription\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eBefore Ordering\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIdentify each controlled opening, its control interface and status-sensing method.\u003c\/li\u003e\n\u003cli\u003eConfirm power requirements from the supplied unit’s label and installation manual.\u003c\/li\u003e\n\u003cli\u003eCheck network coverage and the current subscription and account requirements.\u003c\/li\u003e\n\u003cli\u003eReview lock power, required egress and commissioning responsibilities with the installer.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003ePackage Contents and Separate Requirements\u003c\/h2\u003e\u003cp\u003eThe documented inventory identifies the CAPAC device, paddle antennas, resistors and installation information. Confirm the current carton and the required power supply before ordering. Locks, readers, gate operators, field wiring, internet service, cellular service and the myQ Community subscription are separate requirements unless explicitly included in a complete offer. The hub’s relay outputs control connected equipment; they do not supply all of the power needed by locks or other loads.\u003c\/p\u003e\u003ch2 class=\"safety-warning\"\u003eSafety Warnings — Read Before Installation or Service\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWARNING: Access-control work must preserve safe door and gate operation and required emergency egress. Use a qualified access-control installer.\u003c\/li\u003e\n\u003cli\u003eDisconnect applicable power before wiring. Keep control and power wiring separated as directed, and account for separately powered locks.\u003c\/li\u003e\n\u003cli\u003eDo not power a lock from the controller supply contrary to the manufacturer’s instructions or exceed the documented output ratings.\u003c\/li\u003e\n\u003cli\u003eTest authorized and denied access, status reporting, release and egress behavior before normal use. Protect administrator credentials and verify the site’s behavior during connectivity interruptions.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eRelated Products and Important Differences\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-wireless-security-20-keypad-metal\"\u003eKPW250 wireless keypad\u003c\/a\u003e — a separate access method with its own receiver requirements; not a direct Wiegand input device for CAPAC.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-lmrrul-monitored-retro-reflective-photo-eye\"\u003eLMRRUL monitored photo eye\u003c\/a\u003e — a separate protection device for approved gate operators; cloud access does not replace entrapment protection.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eIs CAPAC a video intercom?\u003c\/h3\u003e\u003cp\u003eNo. It is an access hub; a video intercom is a different product.\u003c\/p\u003e\u003ch3\u003eIs the cloud service included indefinitely with the hardware?\u003c\/h3\u003e\u003cp\u003eNo indefinite service is promised. Confirm the required device subscription and current plan separately.\u003c\/p\u003e\u003ch3\u003eCan any Wiegand reader plug into it?\u003c\/h3\u003e\u003cp\u003eDo not assume that. The documented Wiegand connections are outputs for compatible host-controller arrangements.\u003c\/p\u003e\u003ch3\u003eDoes a relay output power the connected lock?\u003c\/h3\u003e\u003cp\u003eThe relay provides control. Select the separate lock supply and protection specified for the installation.\u003c\/p\u003e\u003ch2\u003eNeed Help Confirming the Right Product?\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/garage-doorparts.com\/pages\/contact\"\u003eContact Garage-DoorParts.com before ordering\u003c\/a\u003e. Send the full equipment model, readable part labels and photographs of the installed assembly. Include the dimensions, electrical configuration or accessory details relevant to your project so the listing can be checked against the actual installation.\u003c\/p\u003e","brand":"Controlled Products","offers":[{"title":"Default Title","offer_id":60655788294430,"sku":"CAPAC","price":246.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0978\/2781\/5710\/files\/capac.png?v=1793139992","url":"https:\/\/garage-doorparts.com\/products\/liftmaster-capac","provider":"garage-doorparts.com","version":"1.0","type":"link"}