{"product_id":"liftmaster-cap4expnd","title":"LiftMaster CAP4EXPND Smart Access Expansion Board — CAPXAP \/CAP4AP Service","description":"\u003cp\u003e\u003cstrong\u003eThe LiftMaster CAP4EXPND is the Smart Access Expansion Board documented for the CAPXAPcontroller panel and CAPXAP-CNTLcontrol board. The manufacturer specifies four relays, four supervised inputs and two Wiegand inputs, and also identifies the board as the service kit for CAP4AP. It is not a stand-alone cloud controller or a universal gate expansion board. Match the host system, current configuration and exact installation instructions before ordering;additional ports must be planned within the supported architecture rather than treated as an unrestricted number of doors.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eCompatibility — Models, Versions and Exclusions\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel or selection point\u003c\/th\u003e\n\u003cth\u003eCompatibility requirement\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPXAP \/CAPXAP-CNTL systems\u003c\/td\u003e\n\u003ctd\u003eUse current expansion wiring and board limits.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAP4AP service replacement\u003c\/td\u003e\n\u003ctd\u003eManufacturer identifies this service role.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK1D8387gate expansion board\u003c\/td\u003e\n\u003ctd\u003eDifferent platform and function.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandalone access control\u003c\/td\u003e\n\u003ctd\u003eHost\/control requirements remain separate.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReader and lock circuits\u003c\/td\u003e\n\u003ctd\u003eVerify exact interface, power and load requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eMap the Extra Ports to the Complete Access System\u003c\/h2\u003e\u003cp\u003eList the additional relays, door contacts, request-to-exit devices and Wiegand readers the project needs. Have the installer map these to the current controller and expansion rules. A relay count is not automatically a door count, and supervised inputs do not establish compatibility with every sensor. Check the existing host and supplied board revision before selecting a module.\u003c\/p\u003e\u003cp\u003ePlan communication wiring, power, enclosure support and the connected lock circuits under the exact instructions. Do not assume relay contacts supply accessory power orcopy wiring from a gate-operator expansion board. After installation, verify each new input, reader and relay function and the site’s required release behavior. Check the controlled opening’s safety independently;an expansion board does not replace monitored gate protection ormake an unsafe entrance suitable for automatic operation.\u003c\/p\u003e\u003ch2\u003eSpecifications and Product Identification\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCAP4EXPND\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct\u003c\/td\u003e\n\u003ctd\u003eSmart Access Expansion Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelays\u003c\/td\u003e\n\u003ctd\u003eFour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupervised inputs\u003c\/td\u003e\n\u003ctd\u003eFour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiegand inputs\u003c\/td\u003e\n\u003ctd\u003eTwo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDocumented hosts\/service\u003c\/td\u003e\n\u003ctd\u003eCAPXAP \/CAPXAP-CNTL;CAP4AP service kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eBefore Ordering\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eRecord exactCAPXAP\/CAPXAP-CNTL host orCAP4APrepair context.\u003c\/li\u003e\n\u003cli\u003eMap required four-relay\/four-input\/two-reader resources.\u003c\/li\u003e\n\u003cli\u003eConfirm board limits, wiring, power and current revision.\u003c\/li\u003e\n\u003cli\u003ePlan full access, input-monitoring and release tests.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003ePackage Contents and Separate Requirements\u003c\/h2\u003e\u003cp\u003eThis offer identifies the CAP4EXPNDboard. A controller cabinet, main control board, reader, keypad, lock, power supply, network equipment, field wiring and service subscription are not promised as included. Confirm current mounting and connection pieces in the board package. The module’s service role for CAP4APdoes not make it a complete replacement controller installation with every accessory. Select additional required components according to the actual host and site design.\u003c\/p\u003e\u003ch2 class=\"safety-warning\"\u003eSafety Warnings — Read Before Installation or Service\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWARNING: Expansion wiring can affect entry and egress. Use qualified access-control personnel and preserve approved emergency release.\u003c\/li\u003e\n\u003cli\u003eIsolate controller, lock supplies and separately powered circuits before wiring. Confirm contacts versuspowered outputs.\u003c\/li\u003e\n\u003cli\u003eDo not exceed documented ratings or substitute a gate expansion board. Do not bypass required protection to force an access function.\u003c\/li\u003e\n\u003cli\u003eTest each reader, input, relay, release function and required controlled-opening protection before normal use.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eRelated Products and Important Differences\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-wireless-security-20-keypad-metal\"\u003eKPW250 wireless keypad\u003c\/a\u003e — a separate wireless access product;not automatically a wired reader for this board.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-lmrrul-monitored-retro-reflective-photo-eye\"\u003eLMRRUL monitored photo eye\u003c\/a\u003e — separate gate protection where approved;input supervision here does not establish a gate safety interface.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eIs it a stand-alone controller?\u003c\/h3\u003e\u003cp\u003eNo. Host and system requirements remain separate.\u003c\/p\u003e\u003ch3\u003eHow many relays are specified?\u003c\/h3\u003e\u003cp\u003eFour, with four supervised inputs and two Wiegand inputs.\u003c\/p\u003e\u003ch3\u003eCan it serviceCAP4AP?\u003c\/h3\u003e\u003cp\u003eThe manufacturer identifies that service-kit role.\u003c\/p\u003e\u003ch3\u003eIs it the same asK1D8387?\u003c\/h3\u003e\u003cp\u003eNo. They belong to different control platforms.\u003c\/p\u003e\u003ch2\u003eNeed Help Confirming the Right Product?\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/garage-doorparts.com\/pages\/contact\"\u003eContact Garage-DoorParts.com before ordering\u003c\/a\u003e. Send the full equipment model, readable part labels and photographs of the installed assembly. Include the dimensions, electrical configuration or accessory details relevant to your project so the listing can be checked against the actual installation.\u003c\/p\u003e","brand":"Controlled Products","offers":[{"title":"Default Title","offer_id":60723611697438,"sku":"CAP4EXPND","price":735.57,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0978\/2781\/5710\/files\/cap4expnd.png?v=1793245128","url":"https:\/\/garage-doorparts.com\/products\/liftmaster-cap4expnd","provider":"garage-doorparts.com","version":"1.0","type":"link"}