{"product_id":"liftmaster-cap4ap","title":"LiftMaster CAP4AP Smart Access Controller — Two Doors or Four Access Points","description":"\u003cp\u003e\u003cstrong\u003eThe LiftMaster CAP4AP is an outdoor-rated smart access controller for managing either two doors or four access points through the myQ Community platform. It combines network connectivity with configurable control connections in an enclosure designed for installation without a separate NEMA box. The manufacturer identifies Wi-Fi, an Ethernet PoE power option and OSDP encrypted communication. Plan the controller around the actual readers, locks, request-to-exit devices and monitored inputs: four relay outputs do not automatically mean four fully equipped bidirectional doors, and the controller is not itself a video intercom or gate operator.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eCompatibility — Models, Versions and Exclusions\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel or selection point\u003c\/th\u003e\n\u003cth\u003eCompatibility requirement\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTwo-door or four-access-point design\u003c\/td\u003e\n\u003ctd\u003eConfirm the full reader, relay and supervised-input allocation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOSDP readers\u003c\/td\u003e\n\u003ctd\u003eVerify approved reader, protocol configuration and secure-communication setup.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiegand devices\u003c\/td\u003e\n\u003ctd\u003eMatch the documented input and credential requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectric locks and gate-control inputs\u003c\/td\u003e\n\u003ctd\u003eCheck separate power needs, relay ratings and approved control wiring.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVideo-intercom or complete operator needs\u003c\/td\u003e\n\u003ctd\u003eSeparate equipment; CAP4AP does not include those functions as a complete system.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003ePlan the Openings, Network and Power Together\u003c\/h2\u003e\u003cp\u003eBegin with an opening-by-opening schedule identifying each reader, lock, door-position input and exit function. Confirm how the controller’s available connections will be allocated before choosing accessories. A relay command is not a substitute for the separate protection functions required at an automated gate, and access-control decisions must preserve the intended emergency egress at every controlled door.\u003c\/p\u003e\u003cp\u003eCheck network availability and select the approved power method for the installation. Wi-Fi connectivity does not mean the controller or connected locks operate without power, while PoE requires suitable network equipment and cabling. Coordinate account commissioning, user permissions and access schedules with the authorized site administrator. Installation of the controller alone does not establish a subscription, credential enrollment or the complete access policy for the property.\u003c\/p\u003e\u003ch2\u003eSpecifications and Product Identification\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCAP4AP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDocumented capacity\u003c\/td\u003e\n\u003ctd\u003eEither two doors or four access points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay outputs\u003c\/td\u003e\n\u003ctd\u003eFour; configurable mapping in myQ Community\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSource input description\u003c\/td\u003e\n\u003ctd\u003eFour supervised inputs, two Wiegand inputs, four OSDP inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower options\u003c\/td\u003e\n\u003ctd\u003e24V DC adapter, provided, or approved PoE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure ratings\u003c\/td\u003e\n\u003ctd\u003eIP54 \/ IK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-4°F to 122°F (-20°C to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e9.25 in. H × 10.29 in. W × 2.58 in. D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eBefore Ordering\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eDefine two-door or four-access-point operation and all required inputs.\u003c\/li\u003e\n\u003cli\u003eConfirm reader protocol, credentials and lock power requirements.\u003c\/li\u003e\n\u003cli\u003eVerify network coverage, approved power and mounting environment.\u003c\/li\u003e\n\u003cli\u003ePlan myQ Community commissioning and test every opening’s release behavior.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003ePackage Contents and Separate Requirements\u003c\/h2\u003e\u003cp\u003eThis offer identifies the CAP4AP controller. The manufacturer states that a 24V DC power adapter is provided; confirm the complete current carton and mounting accessories. Readers, credentials, locks, a PoE network switch, gate operators, video-intercom equipment and any service subscription are separate unless expressly included in the supplier package. The enclosure has provision for a lock; do not assume a separate lock is included merely because the enclosure supports one.\u003c\/p\u003e\u003ch2 class=\"safety-warning\"\u003eSafety Warnings — Read Before Installation or Service\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWARNING: Access-control installation must preserve emergency egress and safe door or gate operation. Use a qualified access-control installer.\u003c\/li\u003e\n\u003cli\u003eDisconnect applicable supplies before wiring, including separate lock power. Observe the documented relay and reader electrical limits.\u003c\/li\u003e\n\u003cli\u003ePreserve the enclosure seals and approved cable entries. IP54 does not authorize submersion or unrestricted pressure washing.\u003c\/li\u003e\n\u003cli\u003eTest credentials, exit requests, door status and required emergency-release behavior. At automated gates, also verify the independent entrapment-protection system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eRelated Products and Important Differences\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-wireless-security-20-keypad-metal\"\u003eKPW250 wireless keypad\u003c\/a\u003e — a different access method requiring a compatible receiver; not an OSDP or Wiegand reader substitution.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-lmrrul-monitored-retro-reflective-photo-eye\"\u003eLMRRUL monitored photo eye\u003c\/a\u003e — a separate gate-protection option for approved operators; controller relays do not replace entrapment sensing.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eDoes CAP4AP control four complete doors?\u003c\/h3\u003e\u003cp\u003eThe manufacturer specifies either two doors or four access points; confirm the required device allocation.\u003c\/p\u003e\u003ch3\u003eIs Wi-Fi the only connection option?\u003c\/h3\u003e\u003cp\u003eNo. The manufacturer also identifies Ethernet with an approved PoE option.\u003c\/p\u003e\u003ch3\u003eAre readers and locks included?\u003c\/h3\u003e\u003cp\u003eNo complete reader-and-lock package is promised in this controller offer.\u003c\/p\u003e\u003ch3\u003eIs CAP4AP a video intercom?\u003c\/h3\u003e\u003cp\u003eNo. It is an access controller; select any required intercom equipment separately.\u003c\/p\u003e\u003ch2\u003eNeed Help Confirming the Right Product?\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/garage-doorparts.com\/pages\/contact\"\u003eContact Garage-DoorParts.com before ordering\u003c\/a\u003e. Send the full equipment model, readable part labels and photographs of the installed assembly. Include the dimensions, electrical configuration or accessory details relevant to your project so the listing can be checked against the actual installation.\u003c\/p\u003e","brand":"Controlled Products","offers":[{"title":"Default Title","offer_id":60723241517342,"sku":"CAP4AP","price":817.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0978\/2781\/5710\/files\/cap4ap.png?v=1793244688","url":"https:\/\/garage-doorparts.com\/products\/liftmaster-cap4ap","provider":"garage-doorparts.com","version":"1.0","type":"link"}