{"product_id":"liftmaster-auxcard","title":"LiftMaster AUXCARD Auxiliary Contacts Option Board — Compatible Logic Operators","description":"\u003cp\u003e\u003cstrong\u003eThe LiftMaster AUXCARD adds auxiliary switching contacts to supported LiftMaster solid-state commercial-door operator controls. It provides normally open and normally closed contact arrangements for documented operating conditions, while the connected device requires its own appropriate external power source. Match the operator generation, option-board slot and intended accessory load before ordering. This is the AUXCARD platform, with its own ratings and programming restrictions; the newer MAXUM AUXREL accessory is a different board and must not be substituted simply because both provide relay outputs.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eCompatibility — Models, Versions and Exclusions\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel or selection point\u003c\/th\u003e\n\u003cth\u003eCompatibility requirement\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperators specifying AUXCARD\u003c\/td\u003e\n\u003ctd\u003eConfirm the option slot and exact logic generation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN4 \/ N4X configurations\u003c\/td\u003e\n\u003ctd\u003eOpen terminals are unavailable for auxiliary use; remote relay control is not available.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal indicator or control circuit\u003c\/td\u003e\n\u003ctd\u003eMatch the load and contact specifications.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncandescent loads\u003c\/td\u003e\n\u003ctd\u003eExcluded by the manufacturer instructions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAXUM AUXREL\u003c\/td\u003e\n\u003ctd\u003eDifferent accessory; no interchangeable fit established.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003ePlan the Contact Function and the External Power Circuit\u003c\/h2\u003e\u003cp\u003eFirst determine what the external device must do when the door moves, stops or loses power. A contact state is not the same as a supply-voltage output. Ask the installer to document the intended response and check the applicable function table before selecting the interface. That avoids an indicator behaving opposite to the intended condition or remaining misleading when the operator is unavailable.\u003c\/p\u003e\u003cp\u003eInspect the existing control enclosure and confirm the required option slot is suitable and available. Identify every external circuit connected to the proposed board so service isolation covers more than the door operator alone. After installation, verify actual behavior through the complete door cycle and relevant stopped or power-loss conditions. Do not treat an auxiliary indication as proof that the doorway is clear or that a required safety device is working.\u003c\/p\u003e\u003ch2\u003eSpecifications and Product Identification\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAUXCARD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct\u003c\/td\u003e\n\u003ctd\u003eAuxiliary contacts option board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl platform\u003c\/td\u003e\n\u003ctd\u003eSupported LiftMaster solid-state commercial operators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact arrangements\u003c\/td\u003e\n\u003ctd\u003eNormally open \/ normally closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum stated contact rating\u003c\/td\u003e\n\u003ctd\u003e10A at 240VAC; application restrictions apply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad exclusion\u003c\/td\u003e\n\u003ctd\u003eNot for incandescent loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal device power\u003c\/td\u003e\n\u003ctd\u003eSeparate suitable source required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eBefore Ordering\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eRecord the complete operator and control-board generation.\u003c\/li\u003e\n\u003cli\u003eConfirm AUXCARD is specified and the correct option slot is available.\u003c\/li\u003e\n\u003cli\u003eIdentify external power, load type and required contact behavior.\u003c\/li\u003e\n\u003cli\u003eCheck N4\/N4X limitations and plan a complete functional test.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003ePackage Contents and Separate Requirements\u003c\/h2\u003e\u003cp\u003eThis offer identifies the AUXCARD option board. External lights, horns, fans, power supplies, remotes, field wiring and a complete operator are not promised as included. Confirm the current package for mounting or connection pieces. Establish the full accessory circuit separately; a relay board alone does not provide every component needed to power or mount a signaling device. Select any additional interface equipment by its own documented electrical requirements.\u003c\/p\u003e\u003ch2 class=\"safety-warning\"\u003eSafety Warnings — Read Before Installation or Service\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWARNING: Isolate operator power and every separately powered external circuit before installing or servicing this board. Use qualified electrical service personnel.\u003c\/li\u003e\n\u003cli\u003eDo not exceed the manufacturer contact limit, and do not connect incandescent loads. A maximum contact rating is not approval for every device of that current.\u003c\/li\u003e\n\u003cli\u003eKeep auxiliary wiring properly enclosed and separated as required. Do not adapt a mismatched board or bypass protection to obtain a desired signal.\u003c\/li\u003e\n\u003cli\u003eTest door operation and all required safety devices after service. Auxiliary contacts do not replace monitored protection or an emergency-stop system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eRelated Products and Important Differences\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-photocell-kit-indoor-only-for-30-wide-openings\"\u003eCPS-U monitored photo eyes\u003c\/a\u003e — separate protection devices for approved commercial-door controls; match the operator and environment.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-extended-duty-trolley-operator\"\u003eTDC12X1BMC MAXUM trolley operator\u003c\/a\u003e — a complete-operator comparison, not evidence that this legacy service part fits MAXUM.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eDoes AUXCARD power the external device?\u003c\/h3\u003e\u003cp\u003eThe accessory circuit needs its own appropriate external power source.\u003c\/p\u003e\u003ch3\u003eCan it switch an incandescent lamp?\u003c\/h3\u003e\u003cp\u003eNo. The manufacturer instructions exclude incandescent loads.\u003c\/p\u003e\u003ch3\u003eIs it the same as AUXREL?\u003c\/h3\u003e\u003cp\u003eNo. AUXREL belongs to a different control platform and has different requirements.\u003c\/p\u003e\u003ch3\u003eAre all functions available on N4\/N4X?\u003c\/h3\u003e\u003cp\u003eNo. Those operators have specific terminal and remote-control restrictions.\u003c\/p\u003e\u003ch2\u003eNeed Help Confirming the Right Product?\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/garage-doorparts.com\/pages\/contact\"\u003eContact Garage-DoorParts.com before ordering\u003c\/a\u003e. Send the full equipment model, readable part labels and photographs of the installed assembly. Include the dimensions, electrical configuration or accessory details relevant to your project so the listing can be checked against the actual installation.\u003c\/p\u003e","brand":"Controlled Products","offers":[{"title":"Default Title","offer_id":60723455623454,"sku":"AUXCARD","price":85.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0978\/2781\/5710\/files\/auxcard.png?v=1793244929","url":"https:\/\/garage-doorparts.com\/products\/liftmaster-auxcard","provider":"garage-doorparts.com","version":"1.0","type":"link"}