{"product_id":"liftmaster-71-26438","title":"LiftMaster 71-26438 Timer-to-Close Field Modification — BG770 \/ BG790","description":"\u003cp\u003e\u003cstrong\u003eThe LiftMaster 71-26438 is the timer-to-close field-modification reference documented for BG770 and BG790 industrial-duty barrier-gate operators. It enables the supported timed-closing arrangement when installed and configured under the exact manufacturer instructions. It is not a universal timer for commercial doors or a substitute for vehicle detection and required protection. Match the actual barrier model, control generation and site operating requirements before ordering. A delay setting does not establish that the lane is clear when the arm begins to close.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eCompatibility — Models, Versions and Exclusions\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel or selection point\u003c\/th\u003e\n\u003cth\u003eCompatibility requirement\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBG770 \/BG790 installations listing71-26438\u003c\/td\u003e\n\u003ctd\u003eMatch control generation and modification instructions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOther barrier operators\u003c\/td\u003e\n\u003ctd\u003eNo universal fit established.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommercial-door timers\u003c\/td\u003e\n\u003ctd\u003eDifferent application; do not transfer settings or wiring.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVehicle detection and entrapment protection\u003c\/td\u003e\n\u003ctd\u003eSeparate system requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower-loss and stopped conditions\u003c\/td\u003e\n\u003ctd\u003eInstaller must verify the documented behavior.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eAssess Timed Closing and the Complete Lane Operation\u003c\/h2\u003e\u003cp\u003eRecord the barrier model and current control configuration before selecting a timer modification. Have the installer document how vehicles enter, wait and leave the lane and which devices inhibit or reverse closing. A timer should be chosen within the operator’s approved control scheme, not added simply because an entrance sometimes remains open. Identify the intended sequence and required safeguards before ordering.\u003c\/p\u003e\u003cp\u003eFollow the exact BG770\/BG790 modification instructions for wiring, configuration and testing. Do not copy a delay range or terminal assignment from another timer accessory. After installation, supervise checks of normal timed closing, interrupted cycles and relevant control conditions as required by the manual. Test detection and required protection independently. An audible warning or elapsed delay does not prove that a vehicle or person is clear of the barrier arm.\u003c\/p\u003e\u003ch2\u003eSpecifications and Product Identification\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart number\u003c\/td\u003e\n\u003ctd\u003e71-26438\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct\u003c\/td\u003e\n\u003ctd\u003eTimer-to-close field modification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDocumented operators\u003c\/td\u003e\n\u003ctd\u003eBG770 \/BG790\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation type\u003c\/td\u003e\n\u003ctd\u003eModel-specific wiring modification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDelay settings and connections\u003c\/td\u003e\n\u003ctd\u003eConfirm exact current instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeparate requirements\u003c\/td\u003e\n\u003ctd\u003eDetection, protection and complete operator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eBefore Ordering\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eRecord full BG770 or BG790 model and control details.\u003c\/li\u003e\n\u003cli\u003eConfirm 71-26438 in the applicable modification instructions.\u003c\/li\u003e\n\u003cli\u003eAssess detection, protection and intended timed sequence.\u003c\/li\u003e\n\u003cli\u003eConfirm package contents and full lane-function test requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003ePackage Contents and Separate Requirements\u003c\/h2\u003e\u003cp\u003eThis offer identifies the 71-26438 timer-to-close field-modification item. Confirm the current timer components, mounting pieces, wiring and instructions supplied with the kit. Vehicle detectors, loops, safety sensors, warning devices, complete field wiring and a barrier operator are not promised as included. The full installation may require separately selected detection and protection components; the timer-kit title alone does not establish a complete automatic-closing entrance package.\u003c\/p\u003e\u003ch2 class=\"safety-warning\"\u003eSafety Warnings — Read Before Installation or Service\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWARNING: Timed closing can start barrier movement without a fresh command from the nearby user. Use qualified gate and access-control personnel.\u003c\/li\u003e\n\u003cli\u003eIsolate all applicable power before wiring and prevent vehicles or pedestrians from entering the service area.\u003c\/li\u003e\n\u003cli\u003eDo not use a delay or warning device as a replacement for required detection and protection. Never bypass safety inputs to make the timer operate.\u003c\/li\u003e\n\u003cli\u003eTest the complete timed sequence and required detection, stopping and protection responses before reopening the lane.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eRelated Products and Important Differences\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/loop-detector\"\u003eLOOPDETLM loop detector\u003c\/a\u003e — a separate vehicle-detection product; verify its exact control compatibility and loop requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-lmrrul-monitored-retro-reflective-photo-eye\"\u003eLMRRUL monitored photo eye\u003c\/a\u003e — a separate protection device only where the individual operator approves it.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhich models are documented?\u003c\/h3\u003e\u003cp\u003eBG770 and BG790.\u003c\/p\u003e\u003ch3\u003eDoes the timer know the lane is clear?\u003c\/h3\u003e\u003cp\u003eA time delay alone does not detect vehicles or people.\u003c\/p\u003e\u003ch3\u003eIs it a universal commercial-door timer?\u003c\/h3\u003e\u003cp\u003eNo. The documented application is these barrier operators.\u003c\/p\u003e\u003ch3\u003eIs a detector included?\u003c\/h3\u003e\u003cp\u003eNo complete detection package is promised; assess it separately.\u003c\/p\u003e\u003ch2\u003eNeed Help Confirming the Right Product?\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/garage-doorparts.com\/pages\/contact\"\u003eContact Garage-DoorParts.com before ordering\u003c\/a\u003e. Send the full equipment model, readable part labels and photographs of the installed assembly. Include the dimensions, electrical configuration or accessory details relevant to your project so the listing can be checked against the actual installation.\u003c\/p\u003e","brand":"Controlled Products","offers":[{"title":"Default Title","offer_id":60723553730846,"sku":"71-26438","price":172.41,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0978\/2781\/5710\/files\/71-26438.png?v=1793245055","url":"https:\/\/garage-doorparts.com\/products\/liftmaster-71-26438","provider":"garage-doorparts.com","version":"1.0","type":"link"}