{"product_id":"liftmaster-03-8024-k","title":"LiftMaster 03-8024-K Reversing Contactor — 24VAC Coil","description":"\u003cp\u003e\u003cstrong\u003eThe LiftMaster 03-8024-K is the reversing-contactor service reference used in documented commercial door and gate operator electrical assemblies. The source identifies a 24VAC coil, which describes the control circuit and must not be confused with the voltage switched to the motor. Select the contactor using the complete operator model, electrical configuration and installed component label. A shared coil voltage alone does not establish matching power-contact ratings, wiring or mounting, and the replacement should follow diagnosis of the motor-control circuit rather than an assumption that every failure to run originates in the contactor.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eCompatibility — Models, Versions and Exclusions\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel or selection point\u003c\/th\u003e\n\u003cth\u003eCompatibility requirement\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSL575 \/ documented legacy SL585 and SL595\u003c\/td\u003e\n\u003ctd\u003eManufacturer parts lists identify this contactor; verify the specific electrical box.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable H \/ GH commercial operators\u003c\/td\u003e\n\u003ctd\u003eMatch the exact contactor-style electrical-box drawing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOther 24V-coil contactors\u003c\/td\u003e\n\u003ctd\u003eNo interchangeability established from coil voltage alone.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolid-state or newer control platforms\u003c\/td\u003e\n\u003ctd\u003eUse their own service references rather than assuming a mechanical contactor replacement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload and protection components\u003c\/td\u003e\n\u003ctd\u003eSeparately selected devices; a contactor does not replace them.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eCheck Both the Control Circuit and the Switched Load\u003c\/h2\u003e\u003cp\u003eRecord the old contactor’s complete markings and the operator’s supply information before ordering. Have qualified personnel inspect the coil circuit, control commands, wiring and motor load. A chattering or non-operating contactor can reflect a supply or control fault, while damaged contacts may indicate a problem that would also affect a new replacement.\u003c\/p\u003e\u003cp\u003eFollow the manufacturer’s terminal identification and connection arrangement. Do not transfer wires solely by physical position on an unfamiliar replacement, and do not infer motor voltage from the coil rating. Reversing arrangements depend on the correct control and interlocking configuration. A replacement contactor is not permission to bypass an overload, defeat a limit or force the mechanism to run.\u003c\/p\u003e\u003ch2\u003eSpecifications and Product Identification\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart number\u003c\/td\u003e\n\u003ctd\u003e03-8024-K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct\u003c\/td\u003e\n\u003ctd\u003eReversing contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSource coil designation\u003c\/td\u003e\n\u003ctd\u003e24VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDocumented examples\u003c\/td\u003e\n\u003ctd\u003eSL575, legacy SL585 \/ SL595 and applicable commercial H \/ GH assemblies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical distinction\u003c\/td\u003e\n\u003ctd\u003eCoil\/control voltage is separate from switched-load voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelection basis\u003c\/td\u003e\n\u003ctd\u003eExact service reference and installed electrical configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eBefore Ordering\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eRecord the complete operator model, supply and installed contactor markings.\u003c\/li\u003e\n\u003cli\u003eConfirm 03-8024-K in the applicable electrical-box drawing.\u003c\/li\u003e\n\u003cli\u003eVerify the coil requirement separately from the power-contact and load requirements.\u003c\/li\u003e\n\u003cli\u003eDiagnose control wiring, motor condition and protective devices before replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003ePackage Contents and Separate Requirements\u003c\/h2\u003e\u003cp\u003eThis offer identifies the contactor service item. An overload relay, transformer, main control board, motor, complete electrical box and field wiring are not promised as included. Confirm the current package for mounting or connection pieces and the exact supplied revision. Parts located together in an electrical-box drawing are separate repair items unless a combined kit is expressly offered.\u003c\/p\u003e\u003ch2 class=\"safety-warning\"\u003eSafety Warnings — Read Before Installation or Service\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWARNING: A contactor can switch hazardous voltage and start a door or gate unexpectedly. Electrical diagnosis and replacement require qualified personnel.\u003c\/li\u003e\n\u003cli\u003eDisconnect and secure all applicable power before service, and restrain the moving equipment according to its manufacturer’s instructions.\u003c\/li\u003e\n\u003cli\u003eNever energize an unverified connection, manually hold contacts closed or bypass electrical and mechanical interlocks to force operation.\u003c\/li\u003e\n\u003cli\u003eRestore covers and verify direction, travel limits, stopping, reversal and required protection devices before normal use.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eRelated Products and Important Differences\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-photocell-kit-indoor-only-for-30-wide-openings\"\u003eCPS-U monitored commercial photo eyes\u003c\/a\u003e — a separate protection component for approved operators and environments; not supplied with this mechanical accessory.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/garage-doorparts.com\/products\/liftmaster-extended-duty-trolley-operator\"\u003eTDC12X1BMC MAXUM trolley operator\u003c\/a\u003e — a complete-operator comparison; verify accessory selection against its own documentation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eDoes 24VAC describe the motor supply?\u003c\/h3\u003e\u003cp\u003eNo. It identifies the source’s coil\/control-voltage specification; the switched circuit has separate requirements.\u003c\/p\u003e\u003ch3\u003eCan any 24VAC contactor replace it?\u003c\/h3\u003e\u003cp\u003eNo. Ratings, contact arrangement, mounting and the exact approved service configuration must match.\u003c\/p\u003e\u003ch3\u003eDoes this include the overload device?\u003c\/h3\u003e\u003cp\u003eAn overload device is not promised as included and must be evaluated separately.\u003c\/p\u003e\u003ch3\u003eWill replacement correct a control-supply fault?\u003c\/h3\u003e\u003cp\u003eNo. The cause of the symptom must be diagnosed and repaired as part of the complete circuit.\u003c\/p\u003e\u003ch2\u003eNeed Help Confirming the Right Product?\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/garage-doorparts.com\/pages\/contact\"\u003eContact Garage-DoorParts.com before ordering\u003c\/a\u003e. Send the full equipment model, readable part labels and photographs of the installed assembly. Include the dimensions, electrical configuration or accessory details relevant to your project so the listing can be checked against the actual installation.\u003c\/p\u003e","brand":"Controlled Products","offers":[{"title":"Default Title","offer_id":60655789277470,"sku":"03-8024-K","price":154.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0978\/2781\/5710\/files\/03-8024-k.png?v=1793139998","url":"https:\/\/garage-doorparts.com\/products\/liftmaster-03-8024-k","provider":"garage-doorparts.com","version":"1.0","type":"link"}